Heating mode
Set Temp
Sleep operation will not undergo temperature shift when it collaborate with below operation. However, it will
execute the delay timer.
Powerful mode operation
o
Stop Condition:
When sleep operation is cancel by pressing respective button until sleep timer reaches 0.0h.
ON/OFF button is pressed.
When sleep operation ends.

14.10 Auto Restart Control

1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be
selected randomly) after power supply resumes.
2. This type of control is not applicable during ON/OFF Timer setting.
3. This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.

14.11 Indication Panel

LED
POWER
Color
White
Light ON
Operation ON
Light OFF
Operation OFF
Note:
If POWER LED is blinking, the possible operation of the unit are Hot Start, operation mode judgment, or ON timer
sampling.
If Timer LED is blinking, there is an abnormality operation occurs.
N
r o
m
l a
1 Hr
TIMER
DEICE
White
White
Timer Setting
Deice ON
ON
Timer Setting
Deice OFF
OFF
S
e l
e
p
T
m i
r e
A
i t c
a v
e t
d
-1°C
Max 9 Hrs
+8/15°C HEAT
White
White
+8/15°C HEAT
Wireless LAN Mode
ON
ON
+8/15°C HEAT
Wireless LAN Mode
OFF
OFF
70
White
TM
nanoe
X Mode ON
TM
nanoe
X Mode OFF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-25xkeCs-35xkeCu-35xkeCs-25xke-5Cu-25xke-5

Table of Contents