Airflow Direction - Panasonic CS-25XKE Service Manual

Table of Contents

Advertisement

14.4 Airflow Direction

1. There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by
vertical vanes).
2. Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat
exchanger temperature and intake air temperature) and manual (angles of direction can be adjusted using
remote control).
14.4.1
Vertical Airflow
Operation Mode
Auto
Cooling/Dry/Fan
Auto with Heat
Exchanger
Temperature
Heating
1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the
angles as stated above. For heating mode operation, the angle of the vane depands on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop. When the air conditioner is
stopped using remote control, the vane will shift to close position.
2. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and
the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the
vane will shift to close position.
C
58°C
B
37°C
A
Indoor Heat
Exchanger Temperature
Figure 1
Airflow Direction
Not yet achieve set
temperature
Achieve set temperature
Auto Swing
Manual
A
B
C
Auto Swing
Manual
50°C
30°C
Upper Vane Angle (°)
1
2
3
4
7 ~ 40
7
7 ~ 40
7
15
20
30
15
54
20
20 ~ 56
15
20
35
50
Closed position/reference position
Reference datum
(Horizontal)
Step 1
Step 2
Step 3
* The horizontal vane angle tolerance is within +/- 5 degree.
66
Lower Vane Angle (°)
5
1
2
3
4 ~ 45
4
4 ~ 45
40
4
14
25
19
43
25
25 ~ 49
56
19
25
34
Step 4
Step 5
4
5
34
45
43
49