Page 1
Version:1.0 User Manual Blood Pressure Monitor TMB-1872-T Arm Type Thank you very much for selecting TRANSTEK Blood Pressure Monitor Guangdong Transtek Medical Electronics Co., Ltd. Zone A, No.105 ,Dongli Road, Torch Development District, TMB-1872-T. Zhongshan,528437,Guangdong,China Please read the user manual carefully and thoroughtly so as to ensure the safe usage of this product, Keep the manual well for further reference in case you have problems.
CATALOGUE CATALOGUE Table of Contents INTRODUCTION........................2 General Description Indications for Use Contraindications Measurement Principle Safety Information LCD Display Signal Monitor Components List BEFORE YOU START......................9 The Choice of Power Supply Installing and Replacing the Batteries Setting Date, Time Select the User Turn on or turn off the voice MEASUREMENT........................14 Tie the Cuff...
Symbol for “TYPE BF APPLIED two years of reliable service. GUIDE MUST BE READ” PARTS” Readings taken by the TMB-1872-T are equivalent to those obtained by a Symbol for “ENVIRONMENT trained observer using the cuff and stethoscope auscultation method. Symbol for “MANUFACTURER”...
Page 4
INTRODUCTION INTRODUCTION CAUTION CAUTION * When measurement, please avoid compression or restriction of the connection tubing. * This device is intended for adult use in homes only. * The device cannot be used with HF surgical equipment at the same time. * The device is not suitable for use on neonatal patients, pregnant women,patients with * The ACCOMPANYING DOCUMENT shall disclose that the SPHYGMOMANOMETER implanted, electronical devices, patients with pre-eclampsia, premature ventricular beats,...
Systolic blood pressure High blood pressure contact the SERVICE PERSONNEL of Transtek. Don’t open or repair the device by yourself in the event of malfunctions. The device must only be serviced, repaired and opened by Diastolic blood pressure Low blood pressure individuals at authorized sales/service centers.
4 Pump 5 Valve List Replace the batteries whenever the below happens 1.Blood Pressure Monitor 2.Cuff (Type BF applied part) 3. 4*AAA batteries (TMB-1872-T) (22~42cm) shows The display is dim The display does not light up 6.Carry bag 5.USB Cable 4.User manual...
BEFORE YOU START BEFORE YOU START Setting Date, Time 4 .Repeat step 2 and 3 to set the [MONTH] and [DAY]. It is important to set the clock before using your blood pressure monitor, so that a time stamp can be assigned to each record that is stored in the memory.
BEFORE YOU START BEFORE YOU START Select the User Turn on or turn off the voice 1. When the monitor is off, press and hold “MEM ” button and “SET ” button to When the monitor is off, press and hold “MEM ”button to enter the mode for turn on or turn off the voice.
MEASUREMENT MEASUREMENT Tie the Cuff Start the Measurement Remove all jewelry, such as watches and bracelets 1.When the monitor is off, press “Start/Stop” button to turn on from your left arm.Note: If your doctor has diagnosed Start the monitor, and it will finish the whole measurement . you with poor circulation in your left arm, use your right arm.
DATA MANAGEMENT DATA MANAGEMENT Recall the Records Delete the Records If you did not get the correct measurement, you can delete 1. When the monitor is off, results by following steps below. please press “MEM” button to show the recent record. A: Delete one record If the records are less than 3 groups, it will display the...
DATA MANAGEMENT INFORMATION FOR USER Delete the Records Tips for Measurement If you did not get the correct measurement, you can delete all results by following steps below. Measurements may be inaccurate if taken in the following circumstances. 1.Hold pressing “MEM” button for 3 seconds when the monitor is in the memory recall mode, the flash...
ABOUT BLOOD PRESSURE INFORMATION FOR USER What are systolic pressure and diastolic pressure? Maintenance Systolic Diastolic When ventricles contract and pump blood out of the Please calibrate the blood pressure monitor in specific institute once heart, the blood pressure reaches its maximum value blood discharging blood entering every two years to ensure the precise measurement.
ABOUT BLOOD PRESSURE TROUBLESHOOTING Why does my blood This section includes a list of error messages and frequently asked questions for problems you may encounter with your blood pressure fluctuate pressure monitor. If the product is not operating as you think it throughout the day? should, check here before arranging for servicing.
For more information about our products, please visit www.transtek.cn.you can condition A relative humidity range of ≤ 93%, non-condensing, get customer service, usual problems and customer download, transtek will serve at a water vapour pressure up to 50hPa you anytime.
Warning:Portable RF communications equipment (including peripherals such as antenna cables and external equipment - Part 1-11: General requirements for basic safety and antennas) should be used no closer than 30 cm (12 inches) to any part of the equipment TMB-1872-T, including essential performance - Collateral standard: Requirements for medical cables specified by the manufacturer.
EMC GUIDANCE EMC GUIDANCE Table 3 Table 2 Guidance and manufacturer’s declaration - electromagnetic Immunity Guidance and manufacturer’s declaration – electromagnetic Immunity IMMUNITY Radiated RF Test Band Service Modulation Modulation Distance (m) Immunity Test IEC 60601-1-2 TEST Compliance level IEC61000-4-3 Frequency (MHz) Test level...
Need help?
Do you have a question about the TMB-1872-T and is the answer not in the manual?
Questions and answers