Installing Vent Components (Figure 46)
Begin the vent system installation by selecting the type of venting to be
installed and the path it will take. Verify clearances are met throughout
the path of the venting system.
Determine how the vent system will be terminated out the side of the
house or through the roof. Verify clearances for the termination.
When selecting a vent system for use with the fireplace, refer to the
"Special Vent Systems" section in this manual to determine which
systems are acceptable.
90° ELBOW
OR
45° ELBOW
90° ELBOW
CEILING FIRESTOP
WALL STRAP
PIPE LENGTH
Figure 46
The following vent systems are acceptable for use with the DVP36SP and DVP36PP series fireplaces:
Duravent® Pro 4" - 6 ⅝"
Selkirk Direct-Temp® 4" - 6 ⅝"
38714-5-0920

VENT SYSTEM IDENTIFICATION

HORIZONTAL
TERMINATION
(MAXIMUM OF
TWO 90° ELBOWS)
Special venting components (Duravent)
See Empire Comfort Systems Retail Price List for Duravent part numbers and pricing.
DVVK-4VP
DVVK-4TP
DVVK-4RP
DVVK-4RE
DVVK-4TSP
DVVK-4FV
VIB6A
VIB7A
VENT SYSTEMS
MetalFab SureSeal® 4" - 6⅝"
Olympia Ventis®
Check all clearances and venting components. Identify if any problems
exist in the vent system. Use Figure 44 on page 27 for top venting to
eliminate issues after installation. Check pipe diameter on vent system
and fireplace to verify the size is the same.
NOTE: All outer connection joints must be sealed with aluminum
tape, screws or silicone sealant rated above 300°F/149°C. The inner
flue joints do not require any sealant.
WALL THIMBLE
Special DV Vent Kits
Available from Empire Comfort Systems, Inc. dealers.
Direct-Vent Fireplace Vent Kit - Vertical, Includes SD46DVAF6,
SD46DVASC, and SD46DVAVCH
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 8 to
11 inch wall thickness, Includes SD46DVA08A, SD46DVA09,
SD46DVAE90, SD46DVAHC, and SD46DVAWT
Direct-Vent Fireplace Vent Kit for Rear Vent, 5 to 7 inch wall
thickness, (standard thru-the-wall venting) includes SD46DVA06,
SD46DVAHC, and SD46DVAWT.
Direct-Vent Fireplace Vent Kit For Rear Vent, Thru-the-wall for
5 to 13 3/4 inch wall thickness.
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 5 to
7 inch wall thickness, Includes SD46DVA06, SD46DVAE90,
SD46DVAHC, and SD46DVAWT.
Vertical Flex Vent Kit 4" x 7"
Vertical Inlet Baffle Kit For 6 5/8" diameter
Vertical Inlet Baffle Kit For 7" diameter
Empire Flexvent Kit DVVK-4F
Empire Flexvent Kit DVVK-4FV
Vertical Flex Vent Kit
VERTICAL
TERMINATION
(MAXIMUM OF
THREE 90° ELBOWS)
STORM COLLAR
ROOF FLASHING