Information Regarding The System Hydraulics - Wolf TopSon F3-1 Installation, Operating And Maintenance Instructions

Table of Contents

Advertisement

Information regarding
the system hydraulics
Flow data: High-Flow (90 l/h x coll), ANRO 30 °C
Solar
Solar
Collector
line
pipe Ø
number
length
(mm)
(m)
15
15 x 1
2
2
30
18 x 1
10
15 x 1
3
3
20
18 x 1
3
30
15 x 1
3
70
18 x 1
15
18 x 1
4
4
30
22 x 1
4
50
18 x 1
10
18 x 1
5
20
22 x 1
5
5
35
18 x 1
5
90
22 x 1
15
22 x 1
6
6
30
18 x 1
6
70
18 x 1
7
15
28 x 1.5
7
15
18 x 1
7
50
22 x 1
50
22 x 1
8
8
100
28 x 1.5
9
20
22 x 1
9
80
28 x 1.5
10
10
22 x 1
10
50
28 x 1.5
All details are recommendations and may vary from system to system. The expansion vessel sizes stated are valid for a static
head of up to 10 metres only.
Pressure drop, F3-1Q, F3-Q with ANRO 30 °C
Flow rate per collector (l/h)
8

Information regarding the system hydraulics

The collectors can be operated with a high specific flow rate (so-called
High-Flow). A dvantages: The collector is well cooled = high collector efficiency
level, low heat losses at the flow line. Disadvantages: High pressure drop
= powerful pump, large pipe cross-sections.
The collectors can be operated with a low specific flow rate (so-called
Low-Flow). Here, the advantages and disadvantages are reversed compared
to the High-Flow operation. An additional advantage, due to the higher flow
temperature, is the effective operation of a stratification cylinder.
Expansion vessel
Pump
DHW
2.5 bar
group
cylinder
F3-1
10
SEM-2-300
18
10
SEM-2-300
18
10
SEM-2-400
25
10
SEM-2-400
35
20
SEM-2-400
25
20
SEM-2-400
35
10
SEM-1-500
35
10
SEM-1-500
50
20
SEM-1-500
35
10
SEM-1-750
50
10
SEM-1-750
50
20
SEM-1-750
50
20
SEM-1-750
50
10
SEM-1-750
80
20
SEM-1-750
50
20
SEM-1-750
50
10
SEM-1-1000
80
20
SEM-1-1000
80
20
SEM-1-1000
80
20
SEM-1-1000
80
20
SEM-1-1000
80
20
SEM-1-1000
80
20
SEM-1-1000
80
20
SEM-1-1000
80
20
SEM-1-1000
105
10 collectors
7 collectors
Flow data: Low-Flow (50 l/h x coll), ANRO 30 °C
Solar
Collector
line
number
length
(m)
F3-Q
18
20
2
2
18
50
35
35
3
3
35
80
35
25
4
4
35
50
50
20
5
5
50
45
50
15
6
50
6
30
50
6
35
50
30
7
50
7
30
7
80
60
80
25
8
80
8
25
8
80
50
80
20
9
80
9
50
9
80
50
105
15
10
80
10
40
10
105
40
105
105
Pressure drop, F3-1 with ANRO 30 °C
5 coll.
3 coll.
1 coll.
Solar
Pump
DHW
pipe Ø
group
cylinder
(mm)
12 x 1
10
SEM-2-300
15 x 1
10
SEM-2-300
15 x 1
10
SEM-2-400
18 x 1
10
SEM-2-400
15 x 1
10
SEM-1-500
18 x 1
10
SEM-2-400
15 x 1
10
SEM-1-500
18 x 1
10
SEM-1-750
15 x 1
10
SEM-1-750
15 x 1
20
SEM-1-750
18 x 1
10
SEM-1-750
18 x 1
10
SEM-1-1000
15 x 1
20
SEM-1-1000
18 x 1
20
SEM-1-1000
18 x 1
10
SEM-1-1000
15 x 1
20
SEM-1-1000
18 x 1
20
SEM-1-1000
18 x 1
10
SEM-1-1000
22 x 1
10
SEM-1-1000
18 x 1
20
SEM-1-1000
18 x 1
10
SEM-1-1000
18 x 1
10
SEM-1-1000
22 x 1
10
SEM-1-1000
Flow rate per collector (l/h)
Expansion vessel
2.5 bar
F3-1
F3-Q
18
18
18
18
25
35
35
35
35
35
35
50
50
50
50
50
50
80
50
80
50
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
105
80
105
10 collectors
7 coll.
5 coll.
3 coll.
1 coll.
3062165_201508

Advertisement

Table of Contents
loading

This manual is also suitable for:

Topson f3-1qTopson f3-q