Download Print this page
Pentair VIFFI ICON 2000 Instructions And Operating Manual
Pentair VIFFI ICON 2000 Instructions And Operating Manual

Pentair VIFFI ICON 2000 Instructions And Operating Manual

Advertisement

Quick Links

Biffi ICON 2000 / ICON 2000 AD
Addendum A to InstructIon And operAtIng mAnuAl
c Ex d e IIB+H2 T4 Gb / c Ex tb IIIC T135°C Db IP66/68
c Ex d e ia IIB+H2 T4 Gb / c Ex tb IIIC T135°C Db IP66/68
index
1
Safety instructions ��������������������������������� 1
1�1
General ����������������������������������������������������� 1
1�2
Identification of main parts ��������������������� 1
2
Check for right application �������������������� 2
2�1
Marking ���������������������������������������������������� 2
3
Applicable general standards and
regulations ���������������������������������������������� 2
4
Terms and conditions ����������������������������� 2
5
Manufacturer's liability ������������������������� 2
6
Storage and pre-installation ����������������� 3
6�1
Storage procedure ����������������������������������� 3
6�2
Checks to be performed before
installation ������������������������������������������������ 3
7
installation ���������������������������������������������� 3
7�1
Working condition ������������������������������������ 3
7�1�1 Models and temperature������������������������� 3
7�1�2 Base unit with extensions [A]
or [B] or [C] ����������������������������������������������� 3
7�2
Identification of entry ������������������������������� 3
7�2�1 Base actuator ������������������������������������������� 3
7�2�2 Base actuator with extension [A]
on the control compartment ������������������� 3
7�2�3 Base actuator with extensions
[B] or [C] on the terminal board
compartment ������������������������������������������� 4
7�3
Wiring ������������������������������������������������������� 4
7�4
Cable connection ������������������������������������� 4
7�5
Installation in ambient with
explosive dusts ����������������������������������������� 4
8
Maintenance �������������������������������������������� 5
8�1
Periodic inspections �������������������������������� 5
8�2
Dismantling and reassembling �������������� 5
8�3
Repairs ����������������������������������������������������� 5
www.pentair.com/valves
1� SAfETy INSTRuCTIONS
1.1 generAl
This Addendum A is an integration to
ICON 2000 main IOM VCIOM-01232 to
prescribe the safety instructions applicable to
all the electric actuators Series ICON 2000 /
ICON 2000 AD either as a base unit either when
they are equipped with an optional extension [A]
for additional entry mounted on the control
compartment or when they are equipped
with an optional extension [B] with additional
entries or with an optional extension [C] with
optional electronic card both mounted on the
terminal board compartment, as identified
by the pictures here below, when they are
installed in Hazardous Areas as defined by the
IEC/EN 60079-10-1 IEC/EN 60079-10-2�
under the same conditions, the optional
extensions [A], [B] or [C], can be mounted on
a base unit ICON 2000 / ICON 2000 AD already
installed on field�
WArning
It is assumed that the installation, setting,
commissioning, maintenance and repair works
are carried out by qualified personnel and
checked by responsible specialists.
Both the base unit ICON 2000 /
ICON 2000 AD and optional extension are
designed in accordance with the applicable
international rules and specifications but in
any case the following regulation must be
observed:
- The general installation and safety
regulations�
- The proper use of personal protective devices
(glasses, clothing, gloves)�
- The proper use of tools, lifting and transport
equipment�
© 2012 Pentair plc� All rights reserved�
1.2 idenTifiCATion of MAin pArTS
Base unit
Base unit with extension [A]
Base unit with extensions [B] or [C]
VCioM-03019-en 15/03

Advertisement

loading

Summary of Contents for Pentair VIFFI ICON 2000

  • Page 1 - The general installation and safety regulations� - The proper use of personal protective devices (glasses, clothing, gloves)� - The proper use of tools, lifting and transport equipment� Base unit with extensions [B] or [C] www.pentair.com/valves VCioM-03019-en 15/03 © 2012 Pentair plc� All rights reserved�...
  • Page 2: Terms And Conditions

    Biffi ICON 2000 / ICON 2000 AD Addendum A to InstructIon And operAtIng mAnuAl 2� CHECk fOR RIGHT 3� APPlICABlE GENERAl 4� TERMS AND CONDITIONS APPlICATION STANDARDS AND Biffi guarantees each single product to be free REGulATIONS from defects and to conform to current goods WArning specifications�...
  • Page 3: Pre-Installation

    Biffi ICON 2000 / ICON 2000 AD Addendum A to InstructIon And operAtIng mAnuAl 6� STORAGE AND 7.1 Working CondiTion iMporTAnT When alternative entries are used, indication PRE-INSTAllATION WArning of the dimensions is imprinted directly on the For the correct utilization with respect to the housing close to the entry.
  • Page 4 Biffi ICON 2000 / ICON 2000 AD Addendum A to InstructIon And operAtIng mAnuAl External earth stud Entries from A to k Internal earth stud 7.2.3 Base actuator with extensions [B] or [C] Two earth points of connection, one internal on the terminal board compartment and one external, are foreseen on the base The extensions [B] or [C] provide up to...
  • Page 5: Maintenance

    All Pentair trademarks and logos are owned by Pentair plc� All other brand or product names are trademarks or registered marks of their respective owners� Because we are continuously improving our products and services, Pentair reserves the right to change product designs and specifications without notice�...

This manual is also suitable for:

Biffi icon 2000 ad