Pentair VIFFI ICON 2000 Instructions And Operating Manual
Pentair VIFFI ICON 2000 Instructions And Operating Manual

Pentair VIFFI ICON 2000 Instructions And Operating Manual

Advertisement

Quick Links

Biffi ICON 2000 / ICON 2000 AD
Addendum A to InstructIon And operAtIng mAnuAl
c Ex d e IIB+H2 T4 Gb / c Ex tb IIIC T135°C Db IP66/68
c Ex d e ia IIB+H2 T4 Gb / c Ex tb IIIC T135°C Db IP66/68
index
1
Safety instructions ��������������������������������� 1
1�1
General ����������������������������������������������������� 1
1�2
Identification of main parts ��������������������� 1
2
Check For Right Application �������������������� 2
2�1
Marking ���������������������������������������������������� 2
3
Applicable general standards and
regulations ���������������������������������������������� 2
4
Terms And Conditions ����������������������������� 2
5
Manufacturer's liability ������������������������� 2
6
Storage and pre-installation ����������������� 3
6�1
Storage Procedure ����������������������������������� 3
6�2
Checks to be performed before
Installation ������������������������������������������������ 3
7
installation ���������������������������������������������� 3
7�1
Working Condition ������������������������������������ 3
7�1�1 Models and temperature������������������������� 3
7�1�2 Base unit with extensions [A]
or [B] or [C] ����������������������������������������������� 3
7�2
Identification Of Entry ������������������������������� 3
7�2�1 Base actuator ������������������������������������������� 3
7�2�2 Base actuator with extension [A]
on the control compartment ������������������� 3
7�2�3 Base actuator with extensions
[B] or [C] on the terminal board
compartment ������������������������������������������� 4
7�3
Wiring ������������������������������������������������������� 4
7�4
Cable Connection ������������������������������������� 4
7�5
Installation in ambient with
explosive dusts ����������������������������������������� 4
8
Maintenance �������������������������������������������� 5
8�1
Periodic Inspections �������������������������������� 5
8�2
Dismantling And Reassembling �������������� 5
8�3
Repairs ����������������������������������������������������� 5
www.pentair.com/valves
1� SAfETy INSTRuCTIONS

1.1 generAl

This Addendum A is an integration to
ICON 2000 main IOM VCIOM-01232 to
prescribe the safety instructions applicable to
all the electric actuators Series ICON 2000 /
ICON 2000 AD either as a base unit either when
they are equipped with an optional extension [A]
for additional entry mounted on the control
compartment or when they are equipped
with an optional extension [B] with additional
entries or with an optional extension [C] with
optional electronic card both mounted on the
terminal board compartment, as identified
by the pictures here below, when they are
installed in Hazardous Areas as defined by the
IEC/EN 60079-10-1 IEC/EN 60079-10-2�
under the same conditions, the optional
extensions [A], [B] or [C], can be mounted on
a base unit ICON 2000 / ICON 2000 AD already
installed on field�
WArning
It is assumed that the installation, setting,
commissioning, maintenance and repair works
are carried out by qualified personnel and
checked by responsible specialists.
Both the base unit ICON 2000 /
ICON 2000 AD and optional extension are
designed in accordance with the applicable
international rules and specifications but in
any case the following regulation must be
observed:
- The general installation and safety
regulations�
- The proper use of personal protective devices
(glasses, clothing, gloves)�
- The proper use of tools, lifting and transport
equipment�
© 2012 Pentair plc� All rights reserved�

1.2 idenTifiCATion of MAin pArTS

Base unit
Base unit with extension [A]
Base unit with extensions [B] or [C]
VCioM-03019-en 15/03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VIFFI ICON 2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Pentair VIFFI ICON 2000

  • Page 1 - The general installation and safety regulations� - The proper use of personal protective devices (glasses, clothing, gloves)� - The proper use of tools, lifting and transport equipment� Base unit with extensions [B] or [C] www.pentair.com/valves VCioM-03019-en 15/03 © 2012 Pentair plc� All rights reserved�...
  • Page 2 Biffi ICON 2000 / ICON 2000 AD Addendum A to InstructIon And operAtIng mAnuAl 2� CHECk fOR RIGHT 3� APPlICABlE GENERAl 4� TERMS AND CONDITIONS APPlICATION STANDARDS AND Biffi guarantees each single product to be free REGulATIONS from defects and to conform to current goods WArning specifications�...
  • Page 3 Biffi ICON 2000 / ICON 2000 AD Addendum A to InstructIon And operAtIng mAnuAl 6� STORAGE AND 7.1 Working CondiTion iMporTAnT When alternative entries are used, indication PRE-INSTAllATION WArning of the dimensions is imprinted directly on the For the correct utilization with respect to the housing close to the entry.
  • Page 4 Biffi ICON 2000 / ICON 2000 AD Addendum A to InstructIon And operAtIng mAnuAl External earth stud Entries from A to k Internal earth stud 7.2.3 Base actuator with extensions [B] or [C] Two earth points of connection, one internal on the terminal board compartment and one external, are foreseen on the base The extensions [B] or [C] provide up to...
  • Page 5 All Pentair trademarks and logos are owned by Pentair plc� All other brand or product names are trademarks or registered marks of their respective owners� Because we are continuously improving our products and services, Pentair reserves the right to change product designs and specifications without notice�...

This manual is also suitable for:

Biffi icon 2000 ad

Table of Contents