Operation - Pentair ONGA 112 Series Owner's Manual

Hi-flo centrifugal pumps
Table of Contents

Advertisement

ELECTRICAL (continued)
Make ground connection to green grounding terminal under capacitor cover lid
marked
and/or E.
230 volt single phase motors are supplied as standard with on winding thermal
overload protection and are designed to plug directly into a 10 amp (GPO)
domestic power supply to local electrical authority specifications.
If service is required to the
pecialised power lead assembly. Warranty is void if unauthorised modifications
are made to any component.
Protect current carrying and grounding conductors from cuts, grease, heat, oil,
and chemicals.
Motor has automatic internal thermal overload protection. If motor has stopped
for unknown reasons, thermal overload may restart motor unexpectedly, which
could cause injury or property damage. Disconnect power before servicing motor.
If any of the preceding is confusing, consult a licensed electrician.

OPERATION

Priming the Pump (Suction lift installations)
NOTICE: 'Priming' refers to the pump expelling all air in the system and
beginning to move water from its source out into the system. It does not
refer only to pouring water into the pump (although pouring water in is usually
the first step).
NOTICE: NEVER run pump dry. Running pump without water in it will
damage seals and can melt impeller, diffuser and seal plate. To prevent damage,
fill pump with water before starting.
1.
Remove priming plug (located on top of the pump casing).
2.
Make sure discharge valve(s) and any hoses on discharge side of the
pump are open.
3.
Fill pump and suction pipe with water.
power lead, it must be replaced with the appropriate s