Appendix; Dmx, Ethernet And Artnet; What Is Artnet - ChamSys MagicQ MQ50 Installation, Software Manual And Warranty Certificate

Console
Hide thumbs Also See for MagicQ MQ50:
Table of Contents

Advertisement

www.chamsys.co.uk
MagicQ Console Quick Start Manual

Appendix

DMX, Ethernet and ArtNet

DMX
DMX data is transmitted in a serial form. This means that there is one cable carrying the data, which is sentbit by
bit (a bit is a 1 or 0), one after another. The entire transmission of DMX data for a DMX universe is known as a
DMX Packet.
The DMX Packet consists of a start code and 512 channel levels.
The start code for DMX is generally 0. The channel section contains the level for that channel.
Ethernet
Ethernet is the technology used to connect computers on a network. Most computers use a protocol called
TCP/IP (Transmission Control Protocol Over Internet Protocol) to communicate over an Ethernet network.
Ethernet transmits the IP address (address of a computer on the network) of the sending computer, followed by
the IP address of the receiving computer, followed by the data. The IP addresses allow the data to be routed to
the correct computer.
On a typical office network, computers will have an IP address of 192.168.1.x, where x is between 0 and 254 (255
is a reserved address). These IP addresses are generally assigned dynamically by the Router on the network using
a protocol called DHCP.
The computers use a subnet mask of 255.255.255.0. This specifies which range of IP addresses are on the
local network. In the example above 255.255.255.0 specifies a range of from 192.168.1.0 to 192.168.1.255
which is a total of 256 addresses.
ArtNet

What is Artnet?

Artnet is a royalty-free communication protocol (language), developed by Artistic License used to transmit DMX
information over a network.
An Artnet network typically uses the 2.x.x.x or 10.x.x.x IP Address scheme using a subnet of 255.0.0.0
It is important to ensure that Art-net data using the Class A IP address scheme is not routed onto the internet.
Ideally a separate lighting network should setup between your QuickQ console and node(s).
Unlike normal office networks, the IP address must be in the range 2.x.x.x or 10.x.x.x, where x is between 0
and 255.
The subnet mask must be set to 255.0.0.0. This means configuring the address of each piece of equipment
on the network manually. QuickQ products are typically set to 10.x.x.x. from the factory.