Summary of Contents for Dimplex Revillusion RBF30WC
Page 1
Revillusion Built-in Electric Firebox. Always comply with the ® warnings and safety instructions contained in this manual to prevent personal injury or property damage. To view the full line of Dimplex products, visit www.dimplex.com 7214620100R04...
CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment. WARNING: Procedures, precautions and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death. www.dimplex.com...
Welcome Thank you for purchasing a Revillusion Built-in Electric Firebox by Dimplex. ® Please use our convenient online registration page to record your model and serial numbers for future reference at: www.dimplex.com/register Model Number MODEL / CAT NO SERIAL NO Serial Number CAUTION: Read all instructions and warnings carefully before starting installation.
Changes or modifications NOTE: the firebox inspected by a reputable not expressly approved by the party electrician before using. responsible for compliance could ⑥ Do not use this firebox outdoors. void user's authority to operate the equipment. www.dimplex.com...
Page 5
IMPORTANT INSTRUCTIONS Special Precautions FCC Compliance WARNING: Remote control contains CAUTION: This unit has been tested a small battery. Keep away from children. and found to comply with the limits for If swallowed, seek medical attention Class B digital device, pursuant to part immediately.
A dedicated circuit will be required if, after installation, the circuit breaker trips or the fuse blows on a regular basis when the heater is operating. Additional appliances on the same circuit may exceed the current rating of the circuit breaker. www.dimplex.com...
Installation Unpacking the Unit The unit comes packed with a protective sheet covering the front of the unit. This sheet is intended to prevent dust and debris from entering during construction. This sheet is designed so that it can be partially removed to complete the wiring and unpacking and can be reinstalled until the final installation is complete.
Page 8
Do not use it in areas where gasoline, paint, or flammable liquids are used or stored. WARNING: The built-in electric firebox must NOT be in direct contact with any building vapor barrier or insulation. www.dimplex.com...
Electrical Bathroom Installation General Electrical This built-in electric firebox must The installation of the built-in electric be protected by a GFI circuit when firebox must comply with the applicable installed in an area where water is Local and/or National Electrical Codes present.
Page 10
N (white) from the power supply. with a cable clamp. Terminate L2 (red) with a wire . Make sure all connections are tight. connector (not included). Connect L1 (black) wire from the built-in electric firebox to the L1 (black) from the power supply. www.dimplex.com...
Page 11
Electrical Direct Power Wiring (240 V) All wiring must be completed prior to installing the built-in electric firebox. Use 3-conductor wires with ground (4 wires total) from the power supply (breaker panel) to the junction box on the built-in electric firebox. WHITE - N WHITE - N 240 V...
Page 12
WHITE - N 120 V WHITE - N POWER BLUE - NH SUPPLY RED - L2 WALL BLACK - L1 BLACK - L1 SWITCH BREAKER PANEL GROUND - G GROUND - G www.dimplex.com...
Page 13
Electrical To install a 120 V wall switch: Pull out the 5 wires marked L1, L2, Secure the two remaining ground N, NH, and G (black, red, white, wires (green) with a ground screw in blue, and green). the main switch wall box. Connect the N (white) and the NH Insert all the wiring of the main (blue) wires from the built-in electric...
Page 14
WHITE - N WHITE - N 240 V POWER BLUE - NH SUPPLY RED - L2 RED - L2 WALL SWITCH BLACK - L1 BLACK - L1 BREAKER GROUND - G GROUND - G PANEL www.dimplex.com...
Page 15
Electrical To install a 240 V wall switch: Pull out the 5 wires marked L1, L2, Connect the L1 wire from the power N, NH, and G. (black, red, white, supply to the L1 terminal of the blue, and green). main power wall switch.
Operation Touch Panel and Remote Controls WARNING: The Revillusion Built-in Electric Firebox must be installed ® properly before it is used. CAUTION: Except for installation and cleaning described in this manual, an authorized service representative should perform any other servicing. The manual controls for the Revillusion Built-in Electric Firebox are located on ®...
Page 18
) and Temp– ( ), on the unit, for 2 seconds. Temperature displays on the screen. Hold both Heat ( ) and Temp– ( ), on the unit, Heat Disable for 2 seconds, when temperature is adjusted "---" displays on the screen. www.dimplex.com...
Page 19
Operation Icon Function Description Press multiple times to change the flame base colors Color from Red to Blue to Off. (The first segment on the display will change from "r" to "b" to blank) This Themes feature is active only when the flame effect is On. Press multiple times to change the LEDs on the sides and back of the unit from Midnight mode to white to Light...
To remove fingerprints or other marks, clean the reflector screen damp cloth. Never use abrasive cleaners. Dry the screen completely with a lint free cloth to prevent water spots. www.dimplex.com...
(except defect the purchaser assumes the entire cost by Glen Dimplex Americas or its authorized of all necessary servicing or repair. service representatives) or otherwise altered.
Page 22
What Glen Dimplex Americas will do in the located if the purchaser’s site is beyond event of a defect...
Page 23
Warranty Glen Dimplex Americas may, in lieu of INCIDENTAL OR CONSEQUENTIAL repair or replacement, choose to refund DAMAGES, SO THE ABOVE LIMITATION the purchase price for such product or OR EXCLUSION MAY NOT APPLY TO THE PURCHASER. part. The purchaser shall not be entitled to on-site or in-house services.