Troubleshooti ng
• Alpha®iQ cleaners are not compati ble with:
the "Diag Box" diagnosti c unit;
-
the "Full Test Diag" diagnosti c soft ware;
-
• The diagnosis described in this procedure is available using a masked functi on from the control box delivered
with the cleaner.
1. Cleaner diagnostics
Test to be conducted out of the water.
-
Connect the cleaner to the control box delivered with the cleaner.
-
Connect the control box's power cable.
-
Turn the cleaner on its back (wheels facing upwards) when rotati ng the wheels forwards and backwards (tracti on
-
test)
On the control box, press
•
Quick mode (fl oor only) fl ashes by default
•
at the same ti me.
Press
to start the cleaner's diagnosti cs. The diagnosti cs process will review the following 5 points in the given
•
order and will stop as soon as an error is identi fi ed:
• During the cleaner's diagnosti cs sequence, do not look directly at the light beam coming from the motor unit.
COM (Communicati on)
tr1 (Tracti on 1)
tr2 (Tracti on 2)
PMP (Pump Motor)
SEnS (Sensor Unit) (depending on the
model)
• Follow the instructi ons, see "2. Cleaner diagnosti cs results".
DIAG.030.A - EN - 2019-12
Technical procedure
Cleaner and control box diagnosti cs
and hold for 10 seconds.
. For control boxes with a screen, the message "diAG" is displayed
"Wait for the test to automati cally end"
During the test:
• All of the control box's LEDs are fl ashing.
• The motor unit's LEDs are lit.
• The sensor unit's LED fl ashes green and turns orange when testi ng the sen-
sor unit.
Alpha™ iQ
1