Check the functionality of the integration module regularly. Clean the body from
dust, cobwebs, and other contaminants as they emerge. Use a soft dry cloth that is
suitable for equipment care. Do not use any substances containing alcohol,
acetone, gasoline, and other active solvents to clean the device.
Malfunction notifications
MultiTransmitter can report malfunctions to the central monitoring station of the
security company, as well as to users through push notifications and SMS.
Notification
Contact is shorted out, [device
name] in [room name]
Lost contact, [device name] in
[room name]
External power has been
disconnected, [device name] in
[room name]
Battery has been disconnected,
[device name] in [room name]
Power supply terminal for
detectors is shorted out, [device
name] in [room name]
Fire detector power supply
Value
MultiTransmitter terminals for
connecting the wired device are
shorted.
Notification can only be
received if an EOL NC
connection is used
The connected wired detector is
torn off.
Notification can be obtained if
an EOL NO connection is used
MultiTransmitter does not have
a 100–240 V power supply
The backup battery is
disconnected from
MultiTransmitter
One of the two MultiTransmitter
power supply outputs is
shorted
MultiTransmitter fire detector
Action
Check the connection of the
wired device or detector for
short circuit.
After the normal state of the
terminals is resumed, you will
receive respective notification
Check the connection of the
wired device or detector to the
integration module
Check for external power supply
on the integration module
Check the connection of the
backup battery to the
integration module
Check the power supply
connection of wired devices or
detectors for short circuit.
After the normal state of the
terminals is resumed, you will
receive respective notification
Check the power supply