P2 (High temperature protection of IPM module diagnosis and solution)
Description: If the temperature of IPM module is higher than limited value, the LED displays this failure code.
Recommended parts to prepare:
Faulty PCB
Connection problems
Troubleshooting and Repair:
Check the fastening screws on the
PCB and IPM radiator.
fixed tightly?
Tighten the screws and apply
silicon grease.
40MPHA-03SM
Are they
NO
Specifications subject to change without notice.
Replace the outdoor
YES
control PCB.