Carrier 40MPHA Service Manual page 10

High wall unit ductless system
Hide thumbs Also See for 40MPHA:
Table of Contents

Advertisement

Sizes 18K to 24K
To CCM Comm.Bus or
485 Wire-controller
CODE
S (Cn16)
Output:0-24VDC Communication port to outdoor
N(CN11)
Input:230VAC High Voltage N line from outdoor
L-IN (CN2)
Input:230VAC High Voltage L line from outdoor
CN 6
Output:230VAC High Voltage Heater port (optional)
CN 12
Output:230V High Voltage Ion port (optional)
CN 4
Output:310VDC High Voltage Indoor DC fan
P_1
Output:0V Ground line welding on PCB
CN 5
Output:12VDC Swing motor 1
CN 14
Output:12VDC Swing motor2 (optional)
CN 43
Output:0-5VDC Micro switch (optional)
CN 44
Output:12VDC Plasma port (optional)
CN 8
Output:12VDC Room temperature sensor (optional)
CN 9
Output:12VDC Pipe temperature sensor
CN10A(CN10)
Output:5VDC Connect to display board
Input:5VDC
4 wires connect to main board
CN 1
3 wires connect to multi-function control board
CN 3
Output:5VDC Wi-Fi controller (optional)
CN 2
Output:5VDC Wire controller (optional)
CN 6
Output:3.3VDC Infrared sensor (operational)
CN 5
Output:5VDC Humidity sensor
CN 4
Output:12VDC Room temperature sensor (optional)
CN42&CN41
Output:5VDC To CCM Comm. Bus or 485 Wire-controller
CN40
Input:5VDC Connect to display board
CN 46
Output:5VDC To Remote Switch
10
CN 2
L-IN
C N11
N
INDOOR UNIT
To Remote Switch
Fig. 6 — Wiring Diagram - Sizes 18K and 24K
MAIN BOARD
DISPLAY BOARD
MULTI-FUNCTION CONTROL BOARD
Specifications subject to change without notice.
PART NAME
Wire Controller
OPTIONAL
40MPHA-03SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

40mphaq09xa340mphaq12xa340mphaq18xa340mphaq24xa3