Firmware setting
Value
Interrupt
IRQ3/IRQ4/IRQ5/IRQ6
/IRQ7/IRQ10/IRQ11
Only with:
IPC327G
IPC377G
Peripheral Type
RS232
Only with:
IPC327G
IPC377G
Onboard Ethernet
own by NONE
1 (LAN 1, X1 P1)
own by PSE(ARM)
control
own by PCH(x86)
Onboard Ethernet
1 Address:
Onboard Ethernet
own by NONE
2 (LAN 2, X2 P1)
own by PSE(ARM)
control
own by PCH(x86)
Onboard Ethernet
2 Address:
Onboard Ethernet
Enabled
3 (LAN 3, X3 P1)
Disabled
control
Only with:
IPC227G
IPC277G
Onboard Ethernet
3 Address:
Only with:
IPC227G
IPC277G
*The Ethernet addresses are merely an example.
Firmware/BIOS description SIMATIC IPC227G, IPC277G, IPC327G, IPC377G
Operating Instructions, 09/2021, A5E50059883-AB
Setting in delivery
Meaning
state
IRQ6
The interrupt is pre-assigned and also recommended.
x
Non-isolated connection for short distances in
interference-free environment.
The onboard Ethernet interface "X1 P1" is disabled.
The onboard Ethernet interface "X1 P1" is controlled by
PSE.
x
x
The onboard Ethernet interface "X1 P1" is controlled by
PCH.
The Onboard Ethernet 1 address is defined with this
value.
The onboard Ethernet interface "X2 P1" is disabled.
The onboard Ethernet interface "X2 P1" is controlled by
PSE.
x
x
The onboard Ethernet interface "X2 P1" is controlled by
PCH.
The Onboard Ethernet 2 address is defined with this
value.
x
The onboard Ethernet interface "X3 P1" is enabled.
The onboard Ethernet interface "X3 P1" is disabled.
The Onboard Ethernet 3 address is defined with this
value.