Service Manual Table of Contents Part Ⅰ : Technical Information ...............1 1. Summary ........................1 2. Specifications ......................3 2.1 Specification Sheet ......................3 2.2 Operation Characteristic Curve ..................11 2.3 Capacity Variation Ratio According to Temperature ............11 2.4 Cooling and Heating Data Sheet in Rated Frequency ...........12 2.5 Noise Curve ........................12 3.
Page 3
Service Manual 9. Maintenance ......................39 9.1 Error Code List .......................39 9.2 Procedure of Troubleshooting ..................46 9.3 Troubleshooting for Normal Malfunction .................60 10. Exploded View and Parts List ..............62 10.1 Indoor Unit ........................62 10.2 Outdoor Unit .........................73 11. Removal Procedure ..................76 11.1 Removal Procedure of Indoor Unit ................76 11.2 Removal Procedure of Outdoor Unit ................81 Appendix:...
Service Manual Part Ⅰ : Technical Information 1. Summary Indoor Unit GWH09MB-K3DNA4G/I GWH09MB-K3DNC1G/I GWH12MB-K3DNA4G/I GWH12MB-K3DNC1G/I GWH09MB-K3DNC5G/I GWH09MB-K3DNC2G/I GWH12MB-K3DNC5G/I GWH12MB-K3DNC2G/I GWH09MB-K3DNB7G/I GWH09MB-K3DNC9G/I GWH12MB-K3DNB7G/I GWH12MB-K3DNC9G/I GWH09MB-K3DNA5G/I GWH12MB-K3DNA2I/I GWH12MB-K3DNA5J/I GWH09MB-K3DNE1G/I GWH09MB-K3DNA3G/I GWH12MB-K3DNE1G/I GWH12MB-K3DNA3I/I Technical Information...
Page 5
TIMER TURBO SLEEP LIGHT Outdoor unit Unit model Unit code Indoor unit model Indoor unit code Model of Outdoor Unit model GWH09MB-K3DNA4G CB161007800 GWH09MB-K3DNA4G/I CB161N07800 GWH09MB-K3DNC1G CB139006000 GWH09MB-K3DNC1G/I CB139N06000 GWH09MB-K3DNC2G CB180001602 GWH09MB-K3DNC2G/I CB180N01602 GWH09MB-K3DNE3G/O GWH09MB-K3DNC5G CB179004000 GWH09MB-K3DNC5G/I CB179N04000 CB404W03600 GWH09MB-K3DNA5G...
Service Manual 2. Specifications 2.1 Specification Sheet 1.GWH09MB-K3DNA4G 2.GWH09MB-K3DNC1G 3.GWH09MB-K3DNC2G Model 4.GWH09MB-K3DNC5G 5.GWH09MB-K3DNA5G 6.GWH09MB-K3DNA3G 7.GWH09MB-K3DND3G 1.CB161007800 2.CB139006000 3.CB180001602 Product Code 4.CB179004000/CB179004002 5.CB162009902 6.CB171011403 7.CB405004400 Rated Voltage 220-240 Power Rated Frequency Supply Phases Power Supply Mode Outdoor Cooling Capacity 2600 Heating Capacity...
Page 7
Service Manual Model of Outdoor Unit GWH09MB-K3DNE3G/O Outdoor Unit Product Code CB404W03600 Compressor Manufacturer/Trademark ZHUHAI LANDA COMPRESSOR CO., LTD. Compressor Model QXA-A091zE190A Compressor Oil RB68EP Compressor Type Rotary L.R.A. 16.5 Compressor RLA Compressor Power Input Overload Protector 1NT11L-6233 Throttling Method Electron expansion valve Operation Temp 16~30...
Page 8
Service Manual 1.GWH09MB-K3DNC2G 2. GWH09MB-K3DNC5G 3.GWH09MB-K3DNB7G 4.GWH09MB-K3DNC9G Model 5.GWH09MB-K3DNE1G 6.GWH09MB-K3DNC1G 7.GWH09MB-K3DNA8G 1.CB180001601 2.CB179004001 3.CB164003001 Product Code 4.CB145006001 5.CB143002101 6.CB139006001 7.CB173006701 Rated Voltage 220-240 Power Rated Frequency Supply Phases Power Supply Mode Outdoor Cooling Capacity 2600 Heating Capacity 3000 Cooling Power Input Heating Power Input Cooling Power Current 3.80...
Page 9
Service Manual Model of Outdoor Unit GWH09MB-K3DNE3G/O Outdoor Unit Product Code CB404W03601 Compressor Manufacturer/Trademark ZHUHAI LANDA COMPRESSOR CO., LTD. Compressor Model QXA-A091zE190A Compressor Oil RB68EP Compressor Type Rotary L.R.A. 16.5 Compressor RLA Compressor Power Input Overload Protector 1NT11L-6233 Throttling Method Electron expansion valve Operation Temp 16~30...
Page 10
Service Manual 1.GWH12MB-K3DNA4G 2.GWH12MB-K3DNC1G 3.GWH12MB-K3DNA5J Model 4.GWH12MB-K3DNA2I 5.GWH12MB-K3DNC2G 6.GWH12MB-K3DNA3I 7.GWH12MB-K3DND3G 1.CB161007900 2.CB139006100 3.CB162010002 Product Code 4.CB181007700 5.CB180001702 6.CB171012900 7.CB405004500 Rated Voltage 220-240 Power Rated Frequency Supply Phases Power Supply Mode Outdoor Cooling Capacity 3500 Heating Capacity 4000 Cooling Power Input 1170 Heating Power Input 1200...
Page 11
Service Manual Model of Outdoor Unit GWH12MB-K3DNE3G/O Outdoor Unit Product Code CB404W03500 Compressor Manufacturer/Trademark ZHUHAI LANDA COMPRESSOR CO., LTD. Compressor Model QXA-A091zE190A Compressor Oil RB68EP Compressor Type Rotary L.R.A. 16.5 Compressor RLA Compressor Power Input Overload Protector 1NT11L-6233 Throttling Method Electron expansion valve Operation Temp 16~30...
Page 12
Service Manual 1.GWH12MB-K3DNB7G 2.GWH12MB-K3DNC9G 3.GWH12MB-K3DNC5G 4.GWH12MB-K3DNE1G Model 5.GWH12MB-K3DNC2G 6.GWH12MB-K3DNC1G 7.GWH12MB-K3DNA8G 1.CB164003101 2.CB145006101 3.CB179004101 4.CB143002201 Product Code 5.CB180001701 6.CB139006101 7.CB173006801 Rated Voltage 220-240 Power Rated Frequency Supply Phases Power Supply Mode Outdoor Cooling Capacity 3500 Heating Capacity 4000 Cooling Power Input 1170 Heating Power Input 1200...
Page 13
Service Manual Model of Outdoor Unit GWH12MB-K3DNE3G/O Outdoor Unit Product Code CB404W03501 Compressor Manufacturer/Trademark ZHUHAI LANDA COMPRESSOR CO., LTD. Compressor Model QXA-A091zE190A Compressor Oil RB68EP Compressor Type Rotary L.R.A. 16.5 Compressor RLA Compressor Power Input Overload Protector 1NT11L-6233 Throttling Method Electron expansion valve Operation Temp 16~30...
Service Manual 2.2 Operation Characteristic Curve Cooling Heating Condition Condition Indoor:DB 20 °C Indoor:DB 27 WB19 °C °C Indoor air flow:Turbo Indoor air flow: Turbo Pipe length:5m Pipe length:5m Voltage:230V Voltage:230V Compressor Speed(rps) Compressor Speed(rps) 2.3 Capacity Variation Ratio According to Temperature Cooling Heating Cooling...
Service Manual 2.4 Cooling and Heating Data Sheet in Rated Frequency Cooling: Rated cooling Pressure of gas pipe Inlet and outlet pipe Compressor condition( connecting indoor and temperature of heat Fan speed of Fan speed of Model frequency (DB/WB) outdoor unit exchanger indoor unit outdoor unit...
Service Manual 4. Refrigerant System Diagram Indoor unit Outdoor unit Gas pipe side Valve 4-Way valve Di s charge Heat Suction Accumlator exchanger Compressor (evaporator) Heat exchanger Liquid pipe (condenser) side Valve Strainer Capillary Electron Strainer expansion valve COOLING HEATING Connection pipe specification: Liquid pipe:1/4"...
Service Manual 5. Electrical Part 5.1 Wiring Diagram ● Instruction Symbol Symbol Color Symbol Symbol Color Symbol Name White Green Jumper cap Yellow Brown COMP Compressor Blue Grounding wire YEGN Yellow/Green Black Violet Orange Note: Jumper cap is used to determine fan speed and the swing angle of horizontal lover for this model. ●...
Page 19
Service Manual ● Outdoor Unit The electrical NOTE: heaters are Motor ground only optional. applies to the iron shell motor. 63610000076 These circuit diagrams are subject to change without notice, please refer to the one supplied with the unit. Technical Information...
Service Manual 5.2 PCB Printed Diagram Indoor Unit ● Top view Name Port of live wire Protective tube Live wire of health function Port of neutral wire Port of indoor fan Communication port Jumper cap Auto button Feedback of indoor fan Port of motor for vertical swing Buzzer Port of display...
Page 21
Service Manual Outdoor Unit ● Top view Name 1 Inductance pin2 2 Inductance pin1 3 Four-wayvalve 4 Compressor electric heater 5 Chassis electric heater 6 Fan neilsbed 7 Electric expansion valve 8 Temp. sensor 9 Main chip 10 EEPROM ● Bottom view Technical Information...
Service Manual 6. Function and Control 6.1 Remote Controller Introduction Buttons on Remote Controller ON/OFF button +/- button FAN button MODE button I FEEL button button button CLOCK button TIMER ON/TIMER OFF button button X-FAN button (Note:X-FAN is the same with BLOW) TEMP button TURBO button SLEEP button...
Page 23
Service Manual 2. "+" or "-" button ● Press “+” or “-“ button once increase or decrease set temperature 1°C.Holding "+" or "-" button, 2s later, set temperature on remote controller will change quickly. On releasing button after setting is finished, temperature indicator on indoor unit will change accordingly. (Temperature can’t be adjusted under auto mode) ●...
Page 24
Service Manual ● After starting up TIMER ON or TIMER OFF, set the constant circulating valid. After that, air conditioner will be turned on or turned off according to setting time. ON/OFF button has no effect on setting. If you don’t need this function, please use remote controller to cancel it. button Press this button can select up&down swing angle.
Page 25
Service Manual Replacement of Batteries in Remote Controller 1.Press the back side of remote controller marked with“ ”as shown in the fig, and then push out the cover of battery box along the arrow direction. 2. Replace two 7# (AAA 1.5V) dry batteries, and make sure the position of “+” polar and “-“ polar are correct. 3.
Service Manual 6.2 Brief Description of Modes and Functions 1. Temperature Parameters ◆ Indoor preset temperature (T preset ◆ Indoor ambient temperature (T amb. 2. Basic Functions Once energized, in no case should the compressor be restarted within less than 3 minutes. In the situation that memory function is available, for the first energization, if the compressor is at stop before de-energization, the compressor will be started without a 3-minute lag;...
Page 27
Service Manual If T ≤T , the unit enters heating mode, in which case the four-way valve, the compressor and the outdoor fan will operate amb. preset +2°C simultaneously, and the indoor fan will run at preset speed in the condition of preset cold air prevention. If T ≥T , the compressor will stop, the outdoor fan will stop with a time lag of 30s, and the indoor fan will stop after 60-second blow...
Page 28
Service Manual 1) Cooling overload a. If T ≤52°C, the unit will return to its original operation state. tube b. If T ≥55°C, frequency rise is not allowed. tube c. If T ≥58°C, the compressor will run at reduced frequency. tube d.
Page 29
Service Manual 2. In heating mode: 2.1 When the initial set temperature is 16°C, the unit will keep on running at this temperature; 2.2 When the initial set temperature is 17~20°C, the temperature will decrease 1°C by every hour after sleep function is set; the temperature will not change after decreasing 1°C;...
Page 30
Service Manual then the wind blade will swing between L and D. The air deflector has 7 swinging states: Location L, Location A, Location B, Location C, Location D, Location L to Location D, stop at any location between L-D (the included angle between L~D is the same). The air deflector will be closed at 0 Location, and the swinging is effectual only on condition that setting the swinging order and the inner fan is running.
Page 31
Service Manual (14)Electric heating band control of outdoor unit ① Compressor electric heating band control: a) Start condition: the compressor is in off status and the T ≤-5°C. outdoor ambient temperature b) Stop condition: the band is off when either of the below condition is met: 1.The compressor is in on status;...
Service Manual Part Ⅱ : Installation and Maintenance 7. Notes for Installation and Maintenance Safety Precautions: 10. If the power cord or connection wire is not long enough, please get the specialized power cord or connection wire Important! from the manufacture or distributor. Prohibit prolong the wire by yourself.
Page 33
Service Manual To ensure safety, please be mindful of the following precautions. ●When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant. Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in injury.
Page 34
Service Manual Main Tools for Installation and Maintenance 1. Level meter, measuring tape 2. Screw driver 3. Impact drill, drill head, electric drill 4. Electroprobe 5. Universal meter 6. Torque wrench, open-end wrench, inner hexagon spanner 7. Electronic leakage detector 8.
Service Manual 8. Installation 8.1 Installation Dimension Diagram Space to the wall At least 15cm At least 15cm Space to the wall Drainage pipe Installation and Maintenance...
Page 36
Service Manual Installation procedures Start installation Preparation before installation Read the requirements select installation Prepare tools for electric connection location Select indoor unit Select outdoor unit installation location installation location Install the support of outdoor unit Install wall-mounting (select it according to the actual situation) frame, drill wall holes Connect pipes of indoor Fix outdoor unit...
Service Manual 8.2 Installation Parts-checking 8.4 Requirement For Electric Connection 1. Safety Precaution Name Name (1) Must follow the electric safety regulations when installing Indoor unit Sealing gum the unit. Outdoor unit Wrapping tape (2) According to the local safety regulations, use qualified Support of outdoor Connection pipe power supply circuit and air switch.
Page 38
Service Manual in the holes. 5. Connect the Pipe of Indoor Unit (3) Fix the wall-mounting frame on the wall with tapping screws (1) Aim the pipe joint at the corresponding bellmouth.(As show (ST4.2X25TA) and then check if the frame is firmly installed by in Fig.5) pulling the frame.
Page 39
Service Manual 7. Connect Wire of Indoor Unit 8. Bind up Pipe (1) Open the panel, remove the screw on the wiring cover and (1) Bind up the connection pipe, power cord and drain hose then take down the cover.(As show in Fig.11) with the band.(As show in Fig.14) (2) Reserve a certain length of drain hose and power cord Screw...
Service Manual Refer to the following table for wrench moment of force: 8.6 Installation of Outdoor Unit Tightening torque(N . m) Hex nut diameter(mm) 1. Fix the Support of Outdoor Unit(Select it According to Φ6 15~20 the Actual Installation Situation) Φ9.52 30~40 Φ12...
Service Manual (3) The water outlet can't be placed in water in order to drain 8.8 Check after Installation and Test smoothly.(As show in Fig.27) Operation 1. Check after Installation Check according to the following requirement after finishing installation. The drain hose can't be fluctuant Items to be checked Possible malfunction Has the unit been...
Service Manual 9. Maintenance 9.1 Error Code List Display Method of Outdoor Display Method of Indoor Unit Unit Indicator has 3 kinds of Indicator Display (during display status and during Malfunction blinking, ON 0.5s and OFF Dual-8 A/C status Possible Causes blinking, ON 0.5s and OFF Name 0.5s)
Page 43
Service Manual Display Method of Outdoor Display Method of Indoor Unit Unit Indicator has 3 kinds of Indicator Display (during display status and during Malfunction blinking, ON 0.5s and OFF Dual-8 A/C status Possible Causes blinking, ON 0.5s and OFF Name 0.5s) Code...
Page 44
Service Manual Display Method of Outdoor Display Method of Indoor Unit Unit Indicator has 3 kinds of Indicator Display (during display status and during Malfunction blinking, ON 0.5s and OFF Dual-8 A/C status Possible Causes blinking, ON 0.5s and OFF Name 0.5s) Code...
Page 45
Service Manual Display Method of Outdoor Display Method of Indoor Unit Unit Indicator has 3 kinds of Indicator Display (during display status and during Malfunction blinking, ON 0.5s and OFF Dual-8 A/C status Possible Causes blinking, ON 0.5s and OFF Name 0.5s) Code...
Page 46
Service Manual Display Method of Outdoor Display Method of Indoor Unit Unit Indicator has 3 kinds of Indicator Display (during display status and during Malfunction blinking, ON 0.5s and OFF Dual-8 A/C status Possible Causes blinking, ON 0.5s and OFF Name 0.5s) Code...
Page 47
Service Manual Display Method of Outdoor Display Method of Indoor Unit Unit Indicator has 3 kinds of Indicator Display (during display status and during Malfunction blinking, ON 0.5s and OFF Dual-8 A/C status Possible Causes blinking, ON 0.5s and OFF Name 0.5s) Code...
Page 48
Service Manual Display Method of Indoor Unit Display Method of Outdoor Unit Indicator Display (during Indicator has 3 kinds of display blinking, ON 0.5s and OFF status and during blinking, ON Dual-8 Malfunction A/C status Possible Causes 0.5s) 0.5s and OFF 0.5s Code Name Operation...
Service Manual 9.2 Procedure of Troubleshooting Indoot Unit 1. Malfunction of Temperature Sensor F1, F2 Main detection points: ● Is the wiring terminal between the temperature sensor and the controller loosened or poorly contacted? ● Is there short circuit due to trip-over of the parts? ●...
Page 50
Service Manual 2. Malfunction of Blocked Protection of IDU Fan Motor H6 Main detection points: ● SmoothlyIs the control terminal of PG motor connected tightly? ● SmoothlyIs the feedback interface of PG motor connected tightly? ● The fan motor can't operate? ●...
Page 51
Service Manual 3. Malfunction of Protection of Jumper Cap C5 Main detection points: ● Is there jumper cap on the mainboard? ● Is the jumper cap inserted correctly and tightly? ● The jumper is broken? ● The motor is broken? ●...
Page 52
Service Manual 4. Capacity charging malfunction (outdoor unit malfunction) (AP1 below means control board of outdoor unit) Main detection points: ● Detect if the voltage of L and N terminal of XT wiring board is between 210VAC-240VAC by alternating voltage meter; ●...
Page 53
Service Manual 5. IPM protection(H5), desynchronizing malfunction(H7), overcurrent of compressor phase current (P5) (AP1 below means control board of outdoor unit) Main detection points: ● Is voltage input within the normal range ● If the control board AP1 is well connected with compressor COMP? If they are loosened? If the connection sequence is correct? ●...
Page 54
Service Manual 6. High temperature and overload protection (E8)(AP1 below means control board of outdoor unit) E8 Main detection points: ● If the outdoor ambient temperature is in normal range; ● If the indoor and outdoor fan are running normally; ●...
Page 55
Service Manual 7. Start-up failure (LC) (AP1 below means control board of outdoor unit) Main detection points: ● If the compressor wiring is correct? ● If the stop time of compressor is sufficient? ● If the compressor is damaged? ● If the refrigerant charging amount is too much? Malfunction diagnosis process: Turn on the unit The stop time is not sufficient and...
Page 56
Service Manual 8. Overload and high discharge temperature malfunction H3/E4 Main detection points: ● If the electronic expansion valve is connected well? Is the electronic expansion valve damaged? ● If the refrigerant is leaked? ● The compressor overload protection terminal is not connected well with the mainboard? ●...
Page 57
Service Manual H3 or E4 is displayed 30min after power off the unit If the overload protector SAT is well connected? Under ambient temperature, test the resistance of overload protector with ohmmeter; resistance value should be<1000ohm Connect wire If the wiring terminal FA of electronic according to wiring expansion valve is well connected? diagram...
Page 58
Service Manual 9. PFC (correction for power factor) malfunction (outdoor unit malfunction) Main detection points: ● Check if power plug is connected well with the socket ● Check if the reactor of outdoor unit is damaged? Malfunction diagnosis process: start If power plug is connected Is the malfunction Connect the plug correctly...
Page 59
Service Manual 10. Communication malfunction (E6) Main detection points: ● Check if the connection wire and the built-in wiring of indoor and outdoor unit are connected well and without damage; ● If the communication circuit of indoor mainboard is damaged? If the communication circuit of outdoor mainboard (AP1) is damaged? Malfunction diagnosis process: If the unit operates normally...
Page 60
Service Manual 11. Malfunction of Overcurrent Protection E5 Main detection points: ● Is the supply voltage unstable with big fluctuation? ● Is the supply voltage too low with overload? ● Hardware trouble? Malfunction diagnosis process: Start Normal fluctuation should be within 10 % Is malfunction Is the supply voltage unstable of the rated voltage on the nameplate...
Page 61
Service Manual 12. Flow chart for outdoor communitcation circuit detecting: (1) Test the voltage between N point of wiring board and communication cable with universal meter. The voltage shall be variable. Otherwise, it might be malfunction of mainboard of indoor unit, or malfunction of mainboard of outdoor unit, or wrong wire connection of indoor and outdoor unit.
Page 62
Service Manual Start Measure voltage at the Test 10 position as shown in the diagram with a voltmeter Value jumping Measure voltage at the Test 15 position as shown in the diagram with a voltmeter Value jumping Fault with outdoor unit Measure voltage at the Test 11 position as shown in the diagram...
Service Manual 9.3 Troubleshooting for Normal Malfunction 1. Air Conditioner Can't be Started Up Possible Causes Discriminating Method (Air conditioner Status) Troubleshooting Confirm whether it's due to power failure. If yes, No power supply, or poor After energization, operation indicator isn’t bright wait for power recovery.
Page 64
Service Manual 4. Air Conditioner is Leaking Possible causes Discriminating method (air conditioner status) Troubleshooting Eliminate the foreign objects inside the drain Drain pipe is blocked Water leaking from indoor unit pipe Drain pipe is broken Water leaking from drain pipe Replace drain pipe Water leaking from the pipe connection place of Wrapping is not tight...
Service Manual 10. Exploded View and Parts List 10.1 Indoor Unit MODE I F EEL CLOCK TIMER X-FAN TEMP TIMER TURBO SLEEP LIGHT The component picture is only for reference; please refer to the actual product. Installation and Maintenance...
Service Manual 11. Removal Procedure Warning: Be sure to wait for a minimum of 20 minutes after turning off all power supplies and discharge the refrigerant completely before removal. 11.1 Removal Procedure of Indoor Unit Steps Procedure 1. Remove filter Open the panel.
Page 80
Service Manual Steps Procedure 3. Remove panel Panel Open the front panel; separate the panel Front panel rotation shaft from the groove fixing the front panel and then removes the front panel. Note: Panel rotation The display of some models is fixed on the panel;...
Page 81
Service Manual Steps Procedure 6. Remove vertical louver Loosen the connection clasps between vertical louver and bottom case to remove vertical louver. Bottom case Vertical louver Clasps 7. Remove electric box assy Loosen the connection clasps between shield cover of electric box sub-assy and electric box, and then remove the shield cover of electric box sub-assy.
Page 82
Service Manual Steps Procedure Remove two screws fixing display. Note: The display of some models is fixed on the panel; unscrew the screws fixing the display on the panel before removing the Display Screws panel. Screw Remove the screw fixing electric box assy and then remove the electric box assy.
Page 83
Service Manual Steps Procedure 9. Remove stepping motor Step motor Screws Remove the screw fixing step motor and then remove the step motor. 10. Remove motor and cross flow blade Remove the screws fixing motor clamp and then remove the motor clamp. Motor clamp Cross flow Remove the screw at the connection...
Service Manual 11.2 Removal Procedure of Outdoor Unit Steps Procedure 1.Remove big handle Before disassamble Remove 1 connection screw fixing big Big handle handleand then removethe big handle. 2. Remove top cover Top cover Remove 3 connection screws among top cover plate, front panel and right sideplate.
Page 85
Service Manual 3.Remove grille and front panel Remove connection screws between the front grille and the front panel. Then remove the front grille. Remove connection screws connecting the front panel with the chassis and the motor support, and then remove the front panel. Grille Panel 4.Remove axial flow blade...
Page 86
Service Manual 6.Remove electric box assy Electric box assy Remove the 2 screws fixing the cover of elec- tric box. Lift to remove the cover. Loosen the wire and disconnect the terminal. Lift to re- move the electric box assy. 7.Remove 4-way valve assy Unscrew the fastening nut of the 4-way Valve 4-way Valve Assy...
Page 87
Service Manual 9.Remove motor and motor support Motor support Remove the 4 tapping screws fixing the motor. Pull out the lead-out wire and remove the Motor motor. Remove the 2 tapping screws fixing the motor support. Lift motor support to re- move it.
Page 88
Service Manual 11.Remove Compressor Remove the 2 screws fixing the gas valve. Unsolder the welding spot connecting gas valve and air return pipe and remove the gas valve. (Note: it is necessary to warp the gas valve when unsoldering the welding spot.) Remove the 2 Liquid valve screws fixing liquid valve.
Service Manual Appendix: Appendix 1: Reference Sheet of Celsius and Fahrenheit Conversion formula for Fahrenheit degree and Celsius degree: Tf=Tcx1.8+32 Set temperature Fahrenheit Fahrenheit Fahrenheit display Fahrenheit display Fahrenheit display Fahrenheit Celsius( Celsius( Celsius( temperature temperature temperature 60.8 69/70 69.8 78/79 78.8 62/63...
Service Manual Appendix 3: Pipe Expanding Method Pipe Note: Pipe cutter Improper pipe expanding is the main cause of refrigerant leakage.Please expand the pipe according to the following steps: Leaning Uneven Burr A:Cut the pip ● Confirm the pipe length according to the distance of indoor unit and outdoor unit. ●...
Service Manual Appendix 4: List of Resistance for Temperature Sensor Resistance Table of Ambient Temperature Sensor for Indoor and Outdoor(15K) Temp( C) Resistance(kΩ) Temp( C) Resistance(kΩ) Temp( Resistance(kΩ) Temp( Resistance(kΩ) 138.1 18.75 3.848 1.071 128.6 17.93 3.711 1.039 121.6 17.14 3.579 1.009 16.39...
Page 92
Service Manual Resistance Table of Tube Temperature Sensors for Indoor and Outdoor (20K) Temp( C) Resistance(kΩ) Temp( C) Resistance(kΩ) Temp( Resistance(kΩ) Temp( Resistance(kΩ) 181.4 25.01 5.13 1.427 171.4 23.9 4.948 1.386 162.1 22.85 4.773 1.346 153.3 21.85 4.605 1.307 20.9 4.443 1.269 137.2...
Page 93
Service Manual Resistance Table of Discharge Temperature Sensor for Outdoor(50K) Temp( C) Resistance(kΩ) Temp( Resistance(kΩ) Temp( C) Resistance(kΩ) Temp( Resistance(kΩ) 853.5 18.34 4.75 799.8 93.42 17.65 4.61 89.07 16.99 4.47 703.8 84.95 16.36 4.33 660.8 81.05 15.75 4.20 620.8 77.35 15.17 4.08 580.6...
Page 94
GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 Email: gree@gree.com.cn Http://www.gree.com HONG KONG GREE ELECTRIC APPLIANCES SALES LIMITED Add: Unit 2612,26/F.,Miramar Tower 132 Nathan Road,TST,Kowloon,HK Tel: (852) 31658898 Fax: (852) 31651029...