SUN2000-(196KTL-H0, 200KTL-H2, 215KTL-H0)
Series
User Manual
No.
Parameter
2
Schedule instruction
valid duration (s)
3
Maximum active
power (kW)
4
OFF at 0% power
limit
5
Active power
change gradient
(%/s)
6
Derated by fixed
active power (kW)
7
Derated by active
power % (%)
8
Night-time reactive
power output
9
Enable reactive
power parameters
at night
10
Night-time reactive
power
compensation
(kVar)
Issue 07 (2021-07-08)
Description
Specifies the time for maintaining
the scheduling instruction.
Specifies the output upper
threshold for the maximum active
power to adapt to different market
requirements.
If this parameter is set to Enable,
the inverter shuts down after
receiving the 0% power limit
command. If this parameter is set
to Disable, the inverter does not
shut down after receiving the 0%
power limit command.
Specifies the change speed of the
inverter active power.
Adjusts the active power output of
the inverter by fixed value.
Adjusts the active power output of
the inverter by percentage.
In some specific application
scenarios, a power grid company
requires that the inverter can
perform reactive power
compensation at night to ensure
that the power factor of the local
power grid meets requirements.
When this parameter is set to
Enable, the inverter outputs
reactive power based on the
setting of Reactive power
compensation at night.
Otherwise, the inverter executes
the remote scheduling command.
During the reactive power
compensation at night, the
reactive power is scheduled by
fixed value.
Copyright © Huawei Technologies Co., Ltd.
7 Man-Machine Interactions
Remarks
When this parameter is set
to 0, the scheduling
instruction takes effect
permanently.
-
-
-
-
If this parameter is set to
100, the inverter outputs
based on the maximum
output power.
-
This parameter is displayed
when Night-time reactive
power output is set to
Enable.
This parameter is displayed
when Night-time reactive
power output and Enable
reactive power parameters
at night are set to Enable.