Operations Related To The Special User - Huawei SUN2000 Series User Manual

Hide thumbs Also See for SUN2000 Series:
Table of Contents

Advertisement

SUN2000-(196KTL-H0, 200KTL-H2, 215KTL-H0)
Series
User Manual
No.
Parameter
14
Shutdown gradient
(%/s)
15
Night-time
hibernation
16
MBUS
communication
17
Delay upgrade
18
RS485-2
communication
19
Duration for
determining short-
time grid
disconnection (ms)

7.1.5 Operations Related to the Special User

If you log in to the app as Special User, you can set grid parameters, protection
parameters, feature parameters, and power adjustment parameters for the
SUN2000.
Issue 07 (2021-07-08)
Description
Specifies the power change speed
when the inverter shuts down.
The inverter monitors PV strings
at night. If this parameter is set to
Enable, the monitoring function
of the inverter will hibernate at
night to reduce power
consumption.
For inverters that support RS485
communication and MBUS
communication, you are advised
to set this parameter to Disable
to reduce power consumption.
This parameter is mainly used in
the upgrade scenarios where the
PV power supply is disconnected
at night due to no sunlight or
unstable at dawn or dusk due to
poor sunlight.
If this parameter is set to Enable,
the RS485-2 port can be used. If
the port is not used, you are
advised to set this parameter to
Disable to reduce power
consumption.
The standards of certain countries
and regions require that the
inverter should not disconnect
from the power grid if the power
grid experiences a short-time
failure. After the fault is rectified,
the inverter output power needs
to be quickly restored.
Copyright © Huawei Technologies Co., Ltd.
7 Man-Machine Interactions
Remarks
-
-
-
After the inverter starts to
upgrade, if Delay upgrade is
set to Enable, the upgrade
package is loaded first. After
the PV power supply recovers
and the activation conditions
are met, the inverter
automatically activates the
upgrade.
-
-
65

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

196ktl-h0200ktl-h2215ktl-h0Sun2000-196ktl-h0Sun2000-200ktl-h2Sun2000-215ktl-h0 ... Show all

Table of Contents