SUN2000-(196KTL-H0, 200KTL-H2, 215KTL-H0)
Series
User Manual

5.4 (Optional) Replacing the Crimping Module

Procedure
Step 1 Replace the crimping module.
Figure 5-6 Replacing the crimping module
----End
5.5 (Optional) Installing the Power Cable of the
Tracking System
Precautions
● A switch-disconnector-fuse or fuse-switch-disconnector with a voltage of no
less than 800 V, current of 16 A, and protection type of gM needs to be
installed between the inverter and the tracker controller for protection.
● The cable between the wiring terminal on the power cable and the switch-
disconnector-fuse or fuse-switch-disconnector should be less than or equal to
2.5 m.
● Connect the power cable of the tracking system before the AC output power
cable. Otherwise, reworking will be caused.
Issue 07 (2021-07-08)
NO TE
If the AC output power cable has a single core, replace the crimping module.
NO TICE