Installation and service must be performed by a qualified installer, service agency or the gas supplier. C#4001609 CERTIFIED TO: ANSI Z21.88 / CSA 2.33 VENTED GAS FIREPLACE HEATERS CSA 2.17 GAS FIRED APPLIANCES FOR HIGH ALTITUDES 50-3058 Version Française: www.enviro.com/fr.html...
Safety Precautions WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS •...
Page 3
NEVER ALLOW CHILDREN shut. TO TOUCH GLASS. • If the Q2GI unit is pulled out of its installation, and the A barrier designed to reduce the risk of burns from the vent-air intake system is disconnected for any reason, hot viewing glass is provided with this appliance and shall...
Table of Contents Safety Precautions......................2 Table of Contents......................4 Codes And Approvals....................5 Specifications......................6 Dimensions.....................6 Rating Label Location..................6 Operating Instructions....................7 Lighting and Turning Off Instructions..............7 Air Shutter......................8 Normal Sounds During Operation..............8 Remote Control Operation.................8 Initializing the System for the First Time............11 Switching to Continuous Pilot................11 Fan Control.....................13 Maintenance And Service....................14 Routine Maintenance..................14...
This appliance has been tested by INTERTEK and found to comply with the established VENTED GAS FIREPLACE HEATER standards in CANADA and the USA as follows: VENTED GAS FIREPLACE HEATER (Q2GI; NATURAL GAS, PROPANE GAS) TESTED TO: ANSI Z21.88-2017/CSA 2.33-2017 VENTED GAS FIREPLACE HEATERS CAN/CGA 2.17-2017 GAS FIRED APPLIANCES FOR HIGH ALTITUDES...
703mm 743mm 6" 153mm 15 13/16" 401mm GAS LINE Figure 1. Q2GI Dimensions - Top Vent & L ating abeL ighting nstRuctions ocation To access the rating label and lighting instructions flip down the control cover. The plates are attached to a length of chain and are never to be tampered with or removed.
Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. ighting anD uRning nstRuctions FOR YOUR SAFETY READ BEFORE OPERATING WARNING:...
The Proflame 2 GTMFL is a modular remote control system that directs the functions of the Q2GI. The Proflame 2 GTMFL is configured to control the on/off main burner operation, its flame levels and provides on/off and Smart thermostatic control of the appliance. The system controls a remotely actuated 120V/60Hz power outlet, and fan speed through six (6) levels.
Page 9
Operating Instructions ystem escRiption The Proflame 2 Remote Control System consists of two (2) elements: 1. Proflame 2 Transmitter. 2. Integrated Fireplace Controller (IFC) and a wiring harness to connect the Receiver to the gas valve, stepper motor and Fan Control Module. ATTENTION! - TURN “OFF”...
Page 10
Operating Instructions CPI Mode Figure 6: Proflame 2 Transmitter LCD Screen. (ifc): ntegRateD iRepLace ontRoLLeR The Proflame 2 IFC (Figure 7) connects directly to the gas valve, stepper motor, pilot, and covection fan with a wiring harness. The IFC is mainly powered by 120 VAC but can also run off a battery backup four (4) AA type batteries for shorter periods of time.
When the Q2GI is turned off press the mode key to index to the constant pilot (CPI) mode icon (see figure 9). Pressing the up arrow key will select Continuous Pilot Ignition (CPI) and pressing the down arrow key will return to IPI.
Page 12
Operating Instructions Turn off the Appliance Press the ON/OFF Key on the Transmitter. The Transmitter LCD display Room Temperature will only show the room temperature and Icon (see Figure 10). A single “beep” from the IFC confirms reception of the command and both the pilot light (if the unit is not set to continuous pilot) and main burner will turn off.
Operating Instructions Fan Control The Q2GI comes with a convection fan that can be controlled with the Transmitter. The fan speed can be adjusted thorugh six (6) speeds. To control the fan press the MODE key (Figure 5) to index to the fan control icon (Figure 13).
The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed. Remove the door (see page 15). The replacement glass will come with a new gasket installed. Remove any silicone remnants from the door.
Maintenance And Service Leaning ecoRative uRfaces Painted and porcelain faces should be wiped with a damp cloth periodically. If a plated face has been purchased, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the finish, including cleaners, polish and finger prints. It is important to note that fingerprints and other marks can leave a permanent stain on plated finishes.
Maintenance And Service uRneR emovaL The burner may need to be removed for a few reasons, including cleaning under the burner or fuel conversion. Proceed only when the unit has completely cooled down. Step 1: Remove the glass door as shown in Step 2: Remove the glass media and the enameled glass the m tray as shown in Figure 20.
Maintenance And Service Conversion Kit Installation: 1. Turn the unit off by pressing the ON/OFF Key on the remote and shut off gas supply at the shut-off valve upstream of the unit. CAUTION: The gas supply must be shut off prior to disconnecting the electrical power and before proceeding with the conversion.
Page 19
13. Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition, operation and proper flame appearance. Confirm the inlet and manifold pressures are within the acceptable ranges as directed in section I . If the Q2GI has ntIal ntallatIon...
Initial Installation QUALIFIED INSTALLERS ONLY ntRoDuction This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement, hearths, facing, mantels, and venting terminations will be covered, as well as the gas and electric systems. There are several installation safety guidelines that must be adhered to. Please carefully read the safety precautions at the front of this manual.
A steel framing plate is included with your Q2GI. The plate does not come installed on the unit but it attaches very easily with a 1/4” hex driver as shown below. This plate is used as a supportive surface to fill in the air gap above the unit in the installation construction.
(in front of the included steel framing plate). The non-combustible is only required directly over the firebox opening and does not need to span the entire width of the framing plate. : The Q2GI can be placed on the floor if desired although it is recommended that it be Ront of raised aleast an inch or higher for more heat sensetive materials such as carpet or linoleum.
Page 23
Initial Installation QUALIFIED INSTALLERS ONLY Minimum Mantle Clearances 12” MANTLE 49” 48” 47” 46” 45” 44” 43” 12" (305mm) 2” MANTLE Mantle 42” 2" (51mm) Mantle M A N T L E D E P T H 4 " (438mm) Figure 27.
The vent length for the Q2GI must be between 6” (150 mm) and 40’ (12.2 m). This model is vented with co-axial 4” intake, 6 5/8” exhaust aluminum or stainless steel approved rigid vent leading into a vertical or horizontal termination cap.
Initial Installation QUALIFIED INSTALLERS ONLY eRmination estRictions Fixed Closed Fixed Openable Closed Openable Termination Cap Air Supply Inlet Gas Meter Restriction Zone (Termination not allowed) Figure 29. Vent Termination Restrictions, refer to Table 3 Table 3: Vent Termination Clearances Letter Canadian Installation US Installation Description...
Direct Vent Pro 4” - 6 5/8” The Q2GI fireplace has been tested and certified for use with AMERICAN METAL PRODUCTS “AMERIVENT DIRECT”, M&G DURAVENT DIRECT VENT PRO. SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available for horizontal and vertical venting.
Page 27
Initial Installation QUALIFIED INSTALLERS ONLY EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent Pro starting collar in conjunction with Secure Vent, Direct-Temp, AmeriVent Direct, and EXCELDirect venting systems. Use of these systems with the Direct Vent Pro starting collar is deemed acceptable and does not affect the Intertek listing of the appliance.
Initial Installation QUALIFIED INSTALLERS ONLY LLowabLe xiaL onfiguRations Figures 30 shows the range of venting options for top vented configurations only using either vertical or horizontal terminations; any layout that remains within the shaded area is acceptable. Having the fewest number of elbows is ideal as they tend to disrupt air movement. Using 45˚ elbows is preferable to using 90˚...
Page 29
Use 4X7 Flex Adapter Kit [50-3788]: This kit will allow you to adapt co-axial flex to the fireplace, make your Any Enviro Approved vent run, then adapt back to rigid venting (flex not Rigid Venting included).
Initial Installation QUALIFIED INSTALLERS ONLY oRizontaL eRmination NOTES: 1. Horizontal pipes must not be level. For every 12” (305 mm) of horizontal travel (away from the stove), there should be at least ¼” (6.4 mm) of vertical travel. Never allow the vent to run downward, as this could cause high temperatures or even present the possibility of a fire.
Initial Installation QUALIFIED INSTALLERS ONLY NOTE: For Simpson Duravent only, place a bead of Mil-Pac or Rutland No 78 Stove and Gasket Cement on the outer edge of the inner exhaust pipe (non-flared end). Push the pipe sections together, then twist about ¼...
Page 32
Initial Installation QUALIFIED INSTALLERS ONLY Step 5. Cut hole in the roof centered on the small hole placed in the roof from Step 2. The hole should be of sufficient size to meet minimum requirements for Clearance to Combustibles, as specified. Continue to assemble lengths of pipe and elbows necessary to reach from the ceiling support box up through the roof line.
Page 33
Initial Installation QUALIFIED INSTALLERS ONLY NOTES: (1) If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3’ (914 mm), to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose (see Figure 34).
Initial Installation QUALIFIED INSTALLERS ONLY onnection anD esting WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certified flexible pipe located on the left side of the unit terminating in a 3/8”...
Initial Installation QUALIFIED INSTALLERS ONLY LectRicaL equiRements The fireplace must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code Part 1, Safety Standards For Electrical Installations, or The National Electrical Code ANSI / NFPA 70 in the US.
Secondary Installation (50-2937): Lass eDia nstaLLation Caution! Always wear gloves when handeling glass media; some pieces may be sharp. A 4 lb bag of glass media is included with the Q2. Open the bag carefully and spread it out evenly over the enameled tray and burner.
Trouble Shooting iagnostic Lash oDes 1. Fail to ignite: If there is no positive ignition, the board will go into lock out and the LED will blink 3 times in intervals until the system is reset. 2. Low battery condition (<4V): the LED indicator will blink one (1) time in intervals. 3.
Page 38
Trouble Shooting Problem Possible Cause Solution The main burner does not Thermostat is not calling for • Adjust the thermostat several degrees above ambient ignite when called for. heat. temperature. Problem with gas valve. • Use a DC voltmeter to measure the voltage across the TPTH and TP terminals.
Parts List Table 10: Q2GI Parts List Reference Part Description Part Number Number Q2GI Owner’s Manual 50-3058 Black Enameled Steel Liner Set (3 Pieces) 50-2978 120 Degree Fan Temperature Sensor EC-001 Door Complete 50-3049 Q2 Safety Screen and Frame 50-3051...
Exclusions conditions herein set forth, this product against defects in material and workmanship An expanded list of exclusions is available at www.enviro.com/help/warranty.html during the specified warranty period starting from the date of original purchase at retail. This warranty does not cover: In the event of a defect of material or workmanship during the specified warranty period, ...
Need help?
Do you have a question about the Q2GI and is the answer not in the manual?
Questions and answers