Enviro Q2GI Owner's Manual
Enviro Q2GI Owner's Manual

Enviro Q2GI Owner's Manual

Direct vent fireplace - ipi
Hide thumbs Also See for Q2GI:

Advertisement

Quick Links

Q2GI
D I R E C T V E N T F I R E P L A C E - I P I
OWNER'S MANUAL
WARNING:
If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage, personal injury
or loss of life. Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
C#4001609
CERTIFIED TO: ANSI Z21.88 / CSA 2.33 VENTED GAS FIREPLACE HEATERS
CSA 2.17 GAS FIRED APPLIANCES FOR HIGH ALTITUDES
50-3058
Version Française: www.enviro.com/fr.html

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Q2GI and is the answer not in the manual?

Questions and answers

Summary of Contents for Enviro Q2GI

  • Page 1 Installation and service must be performed by a qualified installer, service agency or the gas supplier. C#4001609 CERTIFIED TO: ANSI Z21.88 / CSA 2.33 VENTED GAS FIREPLACE HEATERS CSA 2.17 GAS FIRED APPLIANCES FOR HIGH ALTITUDES 50-3058 Version Française: www.enviro.com/fr.html...
  • Page 2: Safety Precautions

    Safety Precautions WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS •...
  • Page 3 NEVER ALLOW CHILDREN shut. TO TOUCH GLASS. • If the Q2GI unit is pulled out of its installation, and the A barrier designed to reduce the risk of burns from the vent-air intake system is disconnected for any reason, hot viewing glass is provided with this appliance and shall...
  • Page 4: Table Of Contents

    Table of Contents Safety Precautions......................2 Table of Contents......................4 Codes And Approvals....................5 Specifications......................6 Dimensions.....................6 Rating Label Location..................6 Operating Instructions....................7 Lighting and Turning Off Instructions..............7 Air Shutter......................8 Normal Sounds During Operation..............8 Remote Control Operation.................8 Initializing the System for the First Time............11 Switching to Continuous Pilot................11 Fan Control.....................13 Maintenance And Service....................14 Routine Maintenance..................14...
  • Page 5: Codes And Approvals

    This appliance has been tested by INTERTEK and found to comply with the established VENTED GAS FIREPLACE HEATER standards in CANADA and the USA as follows: VENTED GAS FIREPLACE HEATER (Q2GI; NATURAL GAS, PROPANE GAS) TESTED TO: ANSI Z21.88-2017/CSA 2.33-2017 VENTED GAS FIREPLACE HEATERS CAN/CGA 2.17-2017 GAS FIRED APPLIANCES FOR HIGH ALTITUDES...
  • Page 6: Specifications

    703mm 743mm 6" 153mm 15 13/16" 401mm GAS LINE Figure 1. Q2GI Dimensions - Top Vent & L ating abeL ighting nstRuctions ocation To access the rating label and lighting instructions flip down the control cover. The plates are attached to a length of chain and are never to be tampered with or removed.
  • Page 7: Operating Instructions

    Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. ighting anD uRning nstRuctions FOR YOUR SAFETY READ BEFORE OPERATING WARNING:...
  • Page 8: Air Shutter

    The Proflame 2 GTMFL is a modular remote control system that directs the functions of the Q2GI. The Proflame 2 GTMFL is configured to control the on/off main burner operation, its flame levels and provides on/off and Smart thermostatic control of the appliance. The system controls a remotely actuated 120V/60Hz power outlet, and fan speed through six (6) levels.
  • Page 9 Operating Instructions ystem escRiption The Proflame 2 Remote Control System consists of two (2) elements: 1. Proflame 2 Transmitter. 2. Integrated Fireplace Controller (IFC) and a wiring harness to connect the Receiver to the gas valve, stepper motor and Fan Control Module. ATTENTION! - TURN “OFF”...
  • Page 10 Operating Instructions CPI Mode Figure 6: Proflame 2 Transmitter LCD Screen. (ifc): ntegRateD iRepLace ontRoLLeR The Proflame 2 IFC (Figure 7) connects directly to the gas valve, stepper motor, pilot, and covection fan with a wiring harness. The IFC is mainly powered by 120 VAC but can also run off a battery backup four (4) AA type batteries for shorter periods of time.
  • Page 11: Initializing The System For The First Time

    When the Q2GI is turned off press the mode key to index to the constant pilot (CPI) mode icon (see figure 9). Pressing the up arrow key will select Continuous Pilot Ignition (CPI) and pressing the down arrow key will return to IPI.
  • Page 12 Operating Instructions Turn off the Appliance Press the ON/OFF Key on the Transmitter. The Transmitter LCD display Room Temperature will only show the room temperature and Icon (see Figure 10). A single “beep” from the IFC confirms reception of the command and both the pilot light (if the unit is not set to continuous pilot) and main burner will turn off.
  • Page 13: Fan Control

    Operating Instructions Fan Control The Q2GI comes with a convection fan that can be controlled with the Transmitter. The fan speed can be adjusted thorugh six (6) speeds. To control the fan press the MODE key (Figure 5) to index to the fan control icon (Figure 13).
  • Page 14: Maintenance And Service

    The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed. Remove the door (see page 15). The replacement glass will come with a new gasket installed. Remove any silicone remnants from the door.
  • Page 15: Cleaning Decorative Surfaces

    Maintenance And Service Leaning ecoRative uRfaces Painted and porcelain faces should be wiped with a damp cloth periodically. If a plated face has been purchased, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the finish, including cleaners, polish and finger prints. It is important to note that fingerprints and other marks can leave a permanent stain on plated finishes.
  • Page 16: Glass Door Removal

    Maintenance And Service uRneR emovaL The burner may need to be removed for a few reasons, including cleaning under the burner or fuel conversion. Proceed only when the unit has completely cooled down. Step 1: Remove the glass door as shown in Step 2: Remove the glass media and the enameled glass the m tray as shown in Figure 20.
  • Page 17: Fuel Conversion

    Kit Parts List for all Q2GI Models: 1 - Orifice (NG - #40 DMS or LP - #55 DMS) as marked 1 - Stepper Regulator with diaphragm...
  • Page 18: Conversion Kit Installation

    Maintenance And Service Conversion Kit Installation: 1. Turn the unit off by pressing the ON/OFF Key on the remote and shut off gas supply at the shut-off valve upstream of the unit. CAUTION: The gas supply must be shut off prior to disconnecting the electrical power and before proceeding with the conversion.
  • Page 19 13. Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition, operation and proper flame appearance. Confirm the inlet and manifold pressures are within the acceptable ranges as directed in section I . If the Q2GI has ntIal ntallatIon...
  • Page 20: Initial Installation

    Initial Installation QUALIFIED INSTALLERS ONLY ntRoDuction This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement, hearths, facing, mantels, and venting terminations will be covered, as well as the gas and electric systems. There are several installation safety guidelines that must be adhered to. Please carefully read the safety precautions at the front of this manual.
  • Page 21: Framing Plate Installation

    A steel framing plate is included with your Q2GI. The plate does not come installed on the unit but it attaches very easily with a 1/4” hex driver as shown below. This plate is used as a supportive surface to fill in the air gap above the unit in the installation construction.
  • Page 22: Mantle And Non-Combustible Clearances

    (in front of the included steel framing plate). The non-combustible is only required directly over the firebox opening and does not need to span the entire width of the framing plate. : The Q2GI can be placed on the floor if desired although it is recommended that it be Ront of raised aleast an inch or higher for more heat sensetive materials such as carpet or linoleum.
  • Page 23 Initial Installation QUALIFIED INSTALLERS ONLY Minimum Mantle Clearances 12” MANTLE 49” 48” 47” 46” 45” 44” 43” 12" (305mm) 2” MANTLE Mantle 42” 2" (51mm) Mantle M A N T L E D E P T H 4 " (438mm) Figure 27.
  • Page 24: Corner Installation

    The vent length for the Q2GI must be between 6” (150 mm) and 40’ (12.2 m). This model is vented with co-axial 4” intake, 6 5/8” exhaust aluminum or stainless steel approved rigid vent leading into a vertical or horizontal termination cap.
  • Page 25: Vent Termination Restrictions

    Initial Installation QUALIFIED INSTALLERS ONLY eRmination estRictions Fixed Closed Fixed Openable Closed Openable Termination Cap Air Supply Inlet Gas Meter Restriction Zone (Termination not allowed) Figure 29. Vent Termination Restrictions, refer to Table 3 Table 3: Vent Termination Clearances Letter Canadian Installation US Installation Description...
  • Page 26: Direct Vent

    Direct Vent Pro 4” - 6 5/8” The Q2GI fireplace has been tested and certified for use with AMERICAN METAL PRODUCTS “AMERIVENT DIRECT”, M&G DURAVENT DIRECT VENT PRO. SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available for horizontal and vertical venting.
  • Page 27 Initial Installation QUALIFIED INSTALLERS ONLY EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent Pro starting collar in conjunction with Secure Vent, Direct-Temp, AmeriVent Direct, and EXCELDirect venting systems. Use of these systems with the Direct Vent Pro starting collar is deemed acceptable and does not affect the Intertek listing of the appliance.
  • Page 28: Allowable Co-Axial Vent Configurations

    Initial Installation QUALIFIED INSTALLERS ONLY LLowabLe xiaL onfiguRations Figures 30 shows the range of venting options for top vented configurations only using either vertical or horizontal terminations; any layout that remains within the shaded area is acceptable. Having the fewest number of elbows is ideal as they tend to disrupt air movement. Using 45˚ elbows is preferable to using 90˚...
  • Page 29 Use 4X7 Flex Adapter Kit [50-3788]: This kit will allow you to adapt co-axial flex to the fireplace, make your Any Enviro Approved vent run, then adapt back to rigid venting (flex not Rigid Venting included).
  • Page 30: Horizontal Termination

    Initial Installation QUALIFIED INSTALLERS ONLY oRizontaL eRmination NOTES: 1. Horizontal pipes must not be level. For every 12” (305 mm) of horizontal travel (away from the stove), there should be at least ¼” (6.4 mm) of vertical travel. Never allow the vent to run downward, as this could cause high temperatures or even present the possibility of a fire.
  • Page 31: Vertical Termination

    Initial Installation QUALIFIED INSTALLERS ONLY NOTE: For Simpson Duravent only, place a bead of Mil-Pac or Rutland No 78 Stove and Gasket Cement on the outer edge of the inner exhaust pipe (non-flared end). Push the pipe sections together, then twist about ¼...
  • Page 32 Initial Installation QUALIFIED INSTALLERS ONLY Step 5. Cut hole in the roof centered on the small hole placed in the roof from Step 2. The hole should be of sufficient size to meet minimum requirements for Clearance to Combustibles, as specified. Continue to assemble lengths of pipe and elbows necessary to reach from the ceiling support box up through the roof line.
  • Page 33 Initial Installation QUALIFIED INSTALLERS ONLY NOTES: (1) If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3’ (914 mm), to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose (see Figure 34).
  • Page 34: Gas Line Connection And Testing

    Initial Installation QUALIFIED INSTALLERS ONLY onnection anD esting WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certified flexible pipe located on the left side of the unit terminating in a 3/8”...
  • Page 35: Electrical Requirements

    Initial Installation QUALIFIED INSTALLERS ONLY LectRicaL equiRements The fireplace must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code Part 1, Safety Standards For Electrical Installations, or The National Electrical Code ANSI / NFPA 70 in the US.
  • Page 36: Secondary Installation

    Secondary Installation (50-2937): Lass eDia nstaLLation Caution! Always wear gloves when handeling glass media; some pieces may be sharp. A 4 lb bag of glass media is included with the Q2. Open the bag carefully and spread it out evenly over the enameled tray and burner.
  • Page 37: Trouble Shooting

    Trouble Shooting iagnostic Lash oDes 1. Fail to ignite: If there is no positive ignition, the board will go into lock out and the LED will blink 3 times in intervals until the system is reset. 2. Low battery condition (<4V): the LED indicator will blink one (1) time in intervals. 3.
  • Page 38 Trouble Shooting Problem Possible Cause Solution The main burner does not Thermostat is not calling for • Adjust the thermostat several degrees above ambient ignite when called for. heat. temperature. Problem with gas valve. • Use a DC voltmeter to measure the voltage across the TPTH and TP terminals.
  • Page 39: Parts List

    Parts List Table 10: Q2GI Parts List Reference Part Description Part Number Number Q2GI Owner’s Manual 50-3058 Black Enameled Steel Liner Set (3 Pieces) 50-2978 120 Degree Fan Temperature Sensor EC-001 Door Complete 50-3049 Q2 Safety Screen and Frame 50-3051...
  • Page 40: Parts Diagram

    Parts Diagram Page 40...
  • Page 41: Notes

    Notes Page 41...
  • Page 42 Notes Page 42...
  • Page 43: Warranty

    Exclusions conditions herein set forth, this product against defects in material and workmanship An expanded list of exclusions is available at www.enviro.com/help/warranty.html during the specified warranty period starting from the date of original purchase at retail. This warranty does not cover: In the event of a defect of material or workmanship during the specified warranty period, ...
  • Page 44: Installation Data Sheet

    NATURAL GAS (NAT) PROPANE(LPG) _________________________________________ INLET GAS PRESSURE:_________in wc PHONE:___________________________________ MAIN BURNER ORIFICE:__________# DMS PILOT ORIFICE #_________OR________in diam. INSTALLER’S SIGNATURE: _________________________________________ MANUFACTURED BY: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3 www.enviro.com July 2019 C-15830 Page 44...

This manual is also suitable for:

Q2g

Table of Contents