1. INTRODUCTION

Thank you for purchasing the Assure Horizontal
SHRU.
This unit allows the heat contained in the shower or
bath waste water to be recovered and transfers this
heat to the cold water before it goes to the shower
mixer tap and/or water heater device.
There is no contact between the water supply and
the drain water.
The transfer of heat is achieved through a double-
walled copper heat exchanger in accordance with
the regulations EN 1717.
When utilizing the Assure Horizontal SHRU, the cold
water feeding into the mixer valve or heater device is
pre-heated to approximately 20 - 25°C, an increase of
approximately 15°C (depending on the type of
configuration and flow of the shower). The result is
a significant energy saving.
IMPORTANT!
Please note that this manual contains important
information, read it carefully before starting the
installation or use of the product.
- Installation and associated work on this
equipment must be carried out by a competent
professional.
- Non-compliance with the recommendations for
installation and use may void any warranty.
- Keep this manual in a safe place for easy
reference when required throughout the life of the
product.
- This product does not have a waste trap. It is a
requirement of the installation to fit an in line trap
upstream from the product itself.
4 Installation Instructions F10-60/170714
NCM/SAP recognition
For the recognition of the Assure Horizontal SHRU
energy saving performance within the National
Calculation Method (NCM) for energy rating of
dwellings known as SAP
(Standard Assessment Procedure) it is vital to
comply with the following:
a) This instruction manual
b) The System Design Checklist
c) The Installation Checklist
d) The Certificate of Installation
b, c & d are supplied as a single document and
are available at: www.ncm-pcdb.or-g.uk/sap
(under 'Technical Documents'). A signed copy
of each should:
1. Be left with the user pack
2. Retained by the installer
3. A copy sent to Baxi (See company details on
Page 16).
(Note: Building control officers may also request a
copy)
A NCM (SAP) identifier label is permanently fixed
to the Assure Horizontal SHRU unit and a second
label attached to a nearby boiler or service
cupboard. The 'model qualifier' denotes the system
installation configuration System A, B or C. For the
permanent label, the model qualifier will state
"Refer to installation certificate, if unknown assume
System B". The actual system configuration will be
recorded on the system design checklist,
installation checklist/ certificate of installation and
the second NCM (SAP) identifier label.