Wi-Fi Configuration; Lges Pv Master - LG LGES-5048 User Manual

Hybrid solar inverter
Hide thumbs Also See for LGES-5048:
Table of Contents

Advertisement

03
SYSTEM OPERATION
3.1 Wi-Fi Configuration
This part shows configuration on web page. You can also complete the configuration with LGES PV
Master. Wi-Fi configuration is absolutely necessary for online monitoring and maintenance.
Preparation:
1. Inverter must be powered up with battery or grid power.
2. Router with available internet access to the website
Step 1
1. Connect Solar-WiFi* to your PC or smart phone (* its
named the last 8 character of the inverter's serial
No.); Password: 12345678.
2. Open browser and login 10.10.100.253 Admin (User):
admin; Password: admin.
3. Then click "OK".
Step 2
1. Click "Start Setup" to choose your router.
2. Then click "Next".
Device information
Firmware version
1.6.9.3.38.2.1.38
MAC address
60:C5:A8:60:33:E1
Wireless AP mode
SSID
Solar-WiFi
IP address
10.10.100.253
Wireless STA mode
Router SSID
WiFi_Burn-in
Encryption method
WAP/WAP2-PSK
Encryption algorithm
Router Password
WiFi_Burn-in
21
Cannot join the network, may be caused by:
No router / weak WiFi signal / password is not correct
Help: Wizard will help you to complete setting with one
minute.
Start Setup
Please select you current wireless network
SSID
AUTH/ENCRY
RSSI
WiFi_Burn-in
WPAPSKWPA2PSK/TKIPAES
66
WiFi_Burn-in
WPAPSKWPA2PSK/TKIPAES
100
WiFi_Burn-in
WPAPSKWPA2PSK/TKIPAES
70
WiFi_Burn-in2
WPAPSKWPA2PSK/TKIPAES
72
Help: When RSSI of the selected Wi-Fi network is lower than
15%, the connection may be unstable.Please select other
available network or shorten the distance between the device
and router. If you wireless router does not broadcast SSID,
please click "Next" and add a wireless network manually.
Back
www.lgresuhomemonitor.com
10.10.100.253
Admin(U) :
admin
Password :
*****
Remember the password(R)
OK
Step 3
1. Fill in the password of ther router, then click
"Next".
2. Click "Complete".
Add wireless network manually
WiFi-Test
Network name (SSID)
Enable
Encryption method
WPA/WPA2-PSK
Encryption algorithm
AES
Disable
Please enter the wireless network passwork:
Password (8-63 bytes)
Router password
show psk
AES
Note: Case sensitive for SSID and password, Please make sure
all parameters of wireless network are matched with router,
including password.
Back
Note:
If the Wi-Fi module fails to connect after correct passwords are entered,
check that there are not special characters used that are not supported by
module.(Supported standard characters: 0~9, a~z, A~Z, supported special
characters: `~!@#$%^&*()_+-=[]\{}|;':<>? ,./'' , characters not mentioned above
Channel
are not supported by default.)
1
Save success!
1
1
Click "Complete", the current configuration will take effect after
1
restart.
Refresh
If you still neet to configure the other pages of information,
please go to complete your required configuration.
Configuration is completed, you can log on the Management
page to restart device by Click on "OK" button.
Confirm to complete?
Next
Back
Note:
1. Please make sure the password, Encryption method / algorithm is the same as the router's.
2. If everything is right well, the Wi-Fi LED on inverter will change from double blink to quadruple blink
then to solid status, which means Wi-Fi has connected to the server successfully.
3. Wi-Fi con guration could also be done on LGES PV Master, details please check on LGES PV Master
Wi-Fi Reset & Reload
Wi-Fi reset means restarting Wi-Fi module. Wi-Fi settings will be reprocessed and saved automat-
ically. Wi-Fi Reload means setting Wi-Fi module back to default factory setting.
is required.
Wi-Fi Reset
Cancel
Short press reset button.
Wi-Fi LED will blink for a few seconds.
Note:
Wi-Fi reset & reload function is only used when:
1. Wi-Fi loses connection to internet or cannot connect to LGES PV Master successfully.
2. Cannot nd "Solar-WiFi signal" or have other Wi-Fi con guration problems.
3. Please do not use this button if Wi-Fi monitoring works well.
4.If you need to replace the module,please use the unlock tool.

3.2 LGES PV Master

LGES PV Master is an external monitoring/ configuration application for
hybrid inverters, used on smart phones or tablet for both Android and iOS
system.
Next
1. Edit system configuration to make the system work as customer needs.
2. Monitor and check the performance of the hybrid system.
please download "LGES PV Master Operation Introduction" at
http://www.lgessbattery.com/au/home-battery/product-info.lg
Complete
Wi-Fi Reload Button
Wi-Fi Reload
Long press reset button (longer than 3s).
Wi-Fi LED will double blink until Wi-Fi
configuration again.
VIRGIN
4:21 PM
100%
95048EHU12345678
Waiting
0.00(kW)
0.00(kW)
0.00(kW)
0.00(kW)
Safety Country
English
Battery Type
RESU10
Operation Model
Normal
Meter Communication Status
CT connection
BMS Communication Status
Alarm warning
Back-Up Switch
Anti-Reverse Function Switch
Overview
Param
Set
22
?
On
Off

Advertisement

Table of Contents
loading

Table of Contents