H4EKO-D

4. TECHNICAL PARAMETERS

Technical parameters
Name of the data
Rated heat output
Efficiency
Required chimney draft
Weight
Ekodesign
Boiler class according to EN 303-5
Volume of water
Chimney outlet diameter
Fuel consumption
Heating water temperature range
Fuel shaft volume
Dimensions of filling space
Length of logs
Combustion duration at max output
The flue gas temperature at Nom. heat. output
Maximum pressure of heating water
Testing pressure of heating water
Warranty fuel
Water content in fuel
Mass flow of flue gas
CO at 10% O2
Dust at 10% O2
Electrical IP
Electrical power
Recommended buffer tank size *[1]
Voltage supply
*[1] The actual size of the buffer tank must be calculated by the designer.
Fuel consumption is directly dependent on the quality and type of fuel used, as well as maintaining the cleanliness of the
internal heat exchange surfaces of the boiler. The smaller the chopped wood is used, the greater the boiler output is
reached, but the burning time per one loading is shortened. On the contrary, if we need less power, we can use thicker
wood to extend burning time on one loading. The position of the primary and secondary air flaps and the speed of the
fan also affect the burning time.
Boiler size
Unit
H416 EKO-D
[kW]
16
[%]
90
Pa
12
[kg]
265
yes
5
[ l ]
33
[mm]
130
[kg/hod]
4,1
[°C]
65 - 85
[ l ]
42
[cm]
35 x 22
[cm]
33
[hod]
> 4
[°C]
137
[MPa]
0,2
[MPa]
0,4
hardwood, logs
[%]
H2O max. 20%
[kg/s]
0,01
[mg/m3]
136
[mg/m3]
52
IP
20
[W]
11
[l]
1000
[V/A]
230/2
4
User manual
Boiler size
Boiler size
H420 EKO-D
H425 EKO-D
20
90
90,2
yes
yes
5
33
130
130
5,1
65 - 85
65 - 85
62
35 x 32
35 x 42
33
> 4
> 4
130
130
0,2
0,2
0,4
0,4
hardwood, logs
hardwood, logs
H2O max. 20%
H2O max. 20%
0,0147
0,0147
-
-
20
22
1000
1000
230/2
230/2
25
5
54
6
82
40
92
31
20
22

Advertisement

Table of Contents
loading

This manual is also suitable for:

H4 eko-d seriesH416 eko-dH420 eko-dH425 eko-d

Table of Contents