H4EKO-D
11. HYDRAULIC SCHEME
CONNECTION WITH 1 HEATING CIRCUIT, MIXING VALVE, BUFFER TANK
No.
Part
1.
CH pump
2.
Mixing valve 1
3.
Temp.sensors KTY
4.
DHW pump
Radiator valves
5.
control
Type / Component / Description
Primary circuit pump
3- or 4-way mixing valve (plugged into the 431N module)
KTY mixing valve sensor 1
KTY DHW sensor
KTY buffer sensor
Domestic hot water pump
Module wifi8 (for 1 objekct)
Zone sensor wifi8 (for 1 zone / room),
Wifi8 valve head (for 1 radiator), (1 zone = max. 6 heads)
(1 module = max. 8 zones / room)
12
User manual
El.connect.
Order number
CH pump
-
Valve
-
Vlave sens.
DHW sens.
345718000020
Buffer sens.
DHW pump
-
-
358120400020
-
358120400040
-
358120400030