Super Match
Match the terminal block numbers and connection cord colors with those of the outdoor unit. Erroneous wiring
may cause burning of the electric parts.
Connect the connection cords firmly to the terminal block. Imperfect installation may cause a fire.
Always fasten the outside covering of the connection cord with the cord clamp.(If the insulator is chafed, electric
leakage may occur.)
Always connect the ground wire.
Wiring of indoor unit
(1) Remove the electrical component box.
(2) Pull out the electrical component box.
(4) Wiring
1. Remove the cord clamp.
2. Process the end of the connection cords to the
dimensions shown in the right figure.
3. Connect the end of the connection cord fully into the
terminal block.
4. Fasten the connection cord with a cord clamp. 5.Fasten
the end of the connection cord with the screw.
(1) Always use a special branch circuit and install a special receptacle to supply power to the room air conditioner.
(2) Use a circuit breaker and receptacle matched to the capacity of the room air conditioner.
(3) The circuit breaker is installed in the permanent wiring. Always use a circuit that can trip all the poles of the
wiring and has an isolation distance of at least 3mm between the contacts of each pole.
(4) Perform wiring work in accordance with standards so that the room air conditioner can be operated safely and
positively.
(5) Install a leakage circuit breaker in accordance with the related laws and regulations and electric company
standards.
CAUTION
(3) Remove the electrical component box cover.
WARNING
91