Haier AB12CS1ERA Service Manual page 70

Hide thumbs Also See for AB12CS1ERA:
Table of Contents

Advertisement

Item
Function
Capacity
Sensible heat ratio
Total power input
Max. power input
EER or COP
Dehumidifying capacity
Power cable
Power source
Running /Max.Running current
Start Current
Unit model (color)
Type × Number
Speed(H-M-L)
Fan
Fan motor input power
Fan motor output power
Air-flow(H-M-L)
Type / Diameter
Heat exchanger
Area
Total area
Indoor
External(L×W×H)
unit
Dimension
Package(L×W×H)
Drainage pipe (material , I.D./O.D.)
Controller (O-Optional,S-Standard)
Fresh air hole dimension
Electricity heater
Sound pressure Noise level
Sound pressure Noise level
Weight (Net / Shipping)
Type / Charge
Recharge quantity
Refrigerant
Max. pipe length without charge
refriigerant
Piping
Liquid
Pipe
Gas
MAX.Drop
Between I.D &O.D
MAX.Piping length
Norminal condition: indoor temperature (cooling): 27℃ DB/19℃ WB, indoor temperature (heating): 20℃ DB
Outdoor temperature(cooling): 35℃ DB/24℃ WB, outdoor temperature(heating): 7℃ DB/6℃ WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a
sound pressure noise level.
Model
kW
kW
W
W/W
10‐³×m³/h
N, V, Hz
A / A
A
r/min
kW
kW
m³/h
mm
mm×mm×mm
mm×mm×mm
mm
Wired
Infrared
mm
kW
(H-M-L)
dB(A)
(H-M-L)
dB(A)
kg / kg
g
g/m
m
mm
mm
m
m
68
Super Match
AC60FS1ERA(S)/1U60IS2ERB(S)
cooling
14(6.0-15)
0.74
4.34(2.0---6.0)
6000
3.23(A)
5.0
/
1, 220~230, 50/60
6.7(2.9-10.0)/10.0
6.5(2.9-10.0)/10.0
/
AC60FS1ERA(S)
CENTRIFUGALX4
1250/1150/1100
0.18
0.105
2000/1800/1400
inner grooved pipe/φ7.0
3
0.312
1580/700/240
1710/790/315
PP 20/25
YR-E14(O)/YR-E16(O)
YR-HD01(S)
200
0
66
53/51/49
54/61
R410A/3300
45
20
9.52
19.05
30
50
heating
15(6.0~17)
4.14(2.0---6.0)
6000
3.62(A)