Haier AB12CS1ERA Service Manual page 280

Hide thumbs Also See for AB12CS1ERA:
Table of Contents

Advertisement

5U45LS1ERA combination and the data
COOLING
Combinations
Comb.
Unit
Unit
Unit
Unit
Unit
A
B
C
D
E
7
— 2.0 —
9
— 2.5 —
12
— 3.5 —
1x1
15
18
— 5.0 —
24
— 6.5 —
7
18
— 2.00 5.00 —
7
24
— 2.00 6.50 —
9
15
— 2.00 4.40 —
9
18
— 2.50 5.00 —
9
24
— 2.50 6.50 —
BI (1x2)
12
15
— 3.50 4.40 —
12
18
— 3.50 5.00 —
12
24 —
18
18
— 5.00 5.00 —
18
24
— 5.00 6.50 —
24
24
— 6.10 6.10 —
7
7
9
— 2.00 2.00 2.50 —
7
7
12
— 2.00 2.00 3.50 —
7
7
15
— 2.00 2.00 4.40
7
7
18
— 2.00 2.00 5.00 —
7
7
24
— 2.00 2.00 6.50 —
7
9
9
— 2.00 2.50 2.50 —
7
9
12
— 2.00 2.50 3.50 —
7
9
15
— 2.00 2.50 4.40 —
7
9
18
— 2.00 2.50 5.00 —
7
9
24
— 2.00 2.50 6.50 —
7
12 12
— 2.00 3.50 3.50 —
7
12 15
— 2.00 3.50 4.40 —
7
12 18
— 2.00 3.50 5.00 —
7
12 24
— 2.00 3.50 6.50 —
9
9
9
— 2.50 2.50 2.50 —
TRI
9
9
12
— 2.50 2.50 3.50 —
(1x3)
9
9
15 —
9
9
18 —
9
9
24 —
9
12 12
— 2.50 3.50 3.50 —
9
12 15
— 2.50 3.50 4.40 —
9
12 18
— 2.50 3.50 5.00 —
9
12 24
— 2.44 3.42 6.34 —
12
12 12
— 3.50 3.50 3.50 —
12
12 15
— 3.50 3.50 4.40 —
12
12 18
— 3.50 3.50 5.00 —
12
12 24
— 3.16 3.16 5.87 —
12
15 18
— 3.28 4.22 4.69 —
12
18 18
— 3.16 4.52 4.52 —
12
18 24
— 2.85 4.07 5.29 —
18
18 18
— 4.07 4.07 4.07 —
Rated capacity Output/
total cooling
kW
capacity(kW)
(Nom. cooling)
Unit
Unit
Unit
Unit
Unit
min.
rated
data
data
A
B
C
D
E
— 1.00 2.00 2.80 0.50 0.62 1.30 2.20 2.77 5.77
— 1.00 2.50 3.10 0.50 0.78 1.34 2.20 3.46 5.93
— 1.00 3.50 4.10 0.50 1.09 1.50 2.20 4.84 6.65
4.4 —
1.30 4.40 5.20 0.50 1.36 1.90 2.22 6.03 8.43
— 1.50 5.00 5.40 0.50 1.56 1.90 2.20 6.92 8.43
— 1.50 6.50 7.40 0.50 2.02 3.00 2.20 8.96 13.31
— 1.00 7.00 8.20 0.50 2.18 3.61 2.15 9.67 16.02
— 1.00 8.50 10.20 0.50 2.65 4.21 2.15 11.76 18.69
— 1.00 6.40 8.50 0.50 1.95 3.50 2.15 8.65 15.53
— 1.00 7.50 8.50 0.50 2.32 3.65 2.15 10.29 16.19
— 1.00 9.00 10.50 0.50 2.70 4.25 2.15 11.98 18.86
— 1.00 7.90 9.50 0.50 2.43 3.50 2.15 10.78 15.53
— 1.00 8.50 9.50 0.50 2.65 3.65 2.15 11.76 16.19
3.50 6.50 —
1.00 10.00 11.50 0.50 3.10 4.25 2.15 13.75 18.86
— 1.00 10.00 10.80 0.50 3.10 4.00 2.15 13.75 17.75
— 1.00 11.50 12.80 0.50 3.57 4.60 2.15 15.84 20.41
— 1.00 12.20 13.50 0.50 3.80 5.20 2.15 16.86 23.07
— 1.50 6.50 8.70 0.55 2.00 4.70 2.50 8.87 20.85
— 1.50 7.50 9.70 0.55 2.30 4.87 2.50 10.20 21.61
1.50 8.40 11.00 0.55 2.51 5.10 2.50 11.14 22.63
— 1.50 9.00 11.00 0.55 2.70 5.22 2.50 11.98 23.16
— 1.50 10.50 13.00 0.55 3.20 5.39 2.50 14.20 23.90
— 1.50 7.00 9.00 0.55 2.15 4.90 2.50 9.54 21.74
— 1.50 8.00 10.00 0.55 2.45 4.90 2.50 10.87 21.74
— 1.50 8.90 11.00 0.55 2.75 5.10 2.50 12.20 22.63
— 1.50 9.50 11.30 0.55 2.90 5.26 2.50 12.87 23.34
— 1.50 11.00 13.30 0.55 3.30 5.39 2.50 14.64 23.90
— 1.50 9.00 11.00 0.55 2.80 3.92 2.50 12.42 17.40
— 1.50 9.90 12.00 0.55 3.04 5.10 2.50 13.49 22.63
— 1.50 10.50 12.30 0.55 3.20 5.26 2.50 14.20 23.34
— 1.50 12.00 11.00 0.55 3.70 5.39 2.50 16.42 23.90
— 1.50 7.50 9.30 0.55 2.30 4.95 2.50 10.20 21.96
— 1.50 8.50 10.30 0.55 2.60 4.95 2.50 11.54 21.96
2.50 2.50 4.40 —
1.50 9.40 11.00 0.55 2.93 5.30 2.50 13.00 23.51
2.50 2.50 5.00 —
1.50 10.00 11.60 0.55 3.10 5.30 2.50 13.75 23.51
2.50 2.50 6.50 —
1.50 11.50 13.50 0.55 3.50 5.39 2.50 15.53 23.90
— 1.50 9.50 11.30 0.55 2.90 4.90 2.50 12.87 21.74
— 1.50 10.40 12.60 0.55 3.16 4.95 2.50 14.02 21.96
— 1.50 11.00 12.60 0.55 3.30 4.95 2.50 14.64 21.96
— 1.50 12.20 13.50 0.55 3.70 5.39 2.50 16.42 23.90
— 1.50 10.50 12.30 0.55 3.25 4.95 2.50 14.42 21.96
— 1.50 11.40 13.50 0.55 3.53 5.30 2.50 15.66 23.51
— 1.50 12.00 13.50 0.55 3.70 5.30 2.50 16.42 23.51
— 1.50 12.20 13.50 0.55 3.77 5.39 2.50 16.73 23.90
— 1.50 12.20 13.50 0.55 3.77 5.39 2.50 16.73 23.90
— 1.50 12.20 13.50 0.55 3.77 5.39 2.50 16.73 23.90
— 1.50 12.20 13.50 0.55 3.77 5.39 2.50 16.73 23.90
— 1.50 12.20 13.50 0.55 3.77 5.39 2.50 16.73 23.90
total power
total current
input
(A)@230V
(kW)
max.
min.
rated
max.
min.
rated
data
data
data
Data
data
data
278
Super Match
EER
(W/W) Energy
Energy
SEER
Label
(W/W)
Label
max.
rated
Data
capacity
3.21
A
5.90
3.21
A
5.90
3.21
A
5.90
3.24
A
5.90
3.21
A
5.90
3.22
A
5.90
3.21
A
6.20
3.21
A
6.20
3.28
A
6.20
3.23
A
6.20
3.33
A
6.20
3.25
A
6.20
3.21
A
6.20
3.23
A
6.20
3.23
A
6.20
3.22
A
6.20
3.21
A
6.20
3.25
A
6.90
3.26
A
6.90
3.35
A
6.90
3.33
A
6.90
3.28
A
6.90
3.26
A
6.90
3.27
A
6.90
3.24
A
6.90
3.28
A
6.90
3.33
A
6.90
3.21
A
6.90
3.26
A
6.90
3.28
A
6.90
3.24
A
6.90
3.26
A
6.90
3.27
A
6.90
3.21
A
6.90
3.23
A
6.90
3.29
A
6.90
3.28
A
6.90
3.29
A
6.90
3.33
A
6.90
3.30
A
6.90
3.23
A
6.90
3.23
A
6.90
3.24
A
6.90
3.24
A
6.90
3.24
A
6.90
3.24
A
6.90
3.24
A
6.90
3.24
A
6.90
A+
A+
A+
A+
A+
A+
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++
A++

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents