Panasonic NN-C69KSMEPG Service Manual page 16

Hide thumbs Also See for NN-C69KSMEPG:
Table of Contents

Advertisement

D. DOOR ASSEMBLY REMOVAL
1) Open the door.
2) Remove two screws holding the Hinge
to the Cavity Ass'y.
CAUTION : Be careful not to damage Door C
by screwdriver.
3) Lift up and pull the door.
NOTE:
1. After replacing the door, be sure to check that the
primary switch, monitor switch, and secondary switch
operate normally.
2. After replacing the door, check for microwave energy
leakage with a survey meter. Microwave energy must
be below the limit of 5 mW/cm
load)
3. When mounting the door assembly to the oven
assembly, be sure to adjust the door assembly parallel
to the chassis. Also adjust so the door has no play
between the inner door surface and oven frame
assembly. If the door assembly is not mounted
properly, microwaves may leak from the clearance
between the door and the oven.
Remove door Assembly
Remove door Assembly
. (with a 275 ml water
2
5-4
E. HIGH VOLTAGE TRANSFORMER
REMOVAL
1) Discharge the high voltage capacitor.
2) Disconnect the leadwire from magnetron, high voltage
transformer, and capacitor.
3) Remove the screw holding the high voltage
transformer to the baseplate.
F.
ORIFICE
ASSEMBLY REMOVAL
1) Discharge the high voltage capacitor.
2) Disconnect the leadwire from fan motor, noise filter
and high voltage capacitor.
3) Remove the two screws holding the orifice
oven cavity and remove the high voltage
to the
earth screw.
4) Remove the screw of the capacitor bracket.
5) Remove the two screws holding the fan motor ASS'Y
to the Orifice
ASS'Y
.
G. HIGH VOLTAGE CAPACITOR AND
DIODE REMOVAL
1) Discharge the high voltage capacitor.
2) Disconnect the leadwire from fan motor, noise filter
and high voltage capacitor.
3) Remove the screw holding the Orifice
cavity and remove the high voltage diode
the oven
earth screw.
4) Remove the screw holding the high voltage capacitor
bracket.
ASS'Y
diode
ASS'Y
to