ELECTRICAL CONNECTIONS

Cavo sensore
Each 24 VAC electric valve is equipped with two black cables. The fi rst one identifi es the number of
the area and it will be connected to one of the outputs numbered in the terminal compartment and
the second one is the common cable that will be connected to the Exit C in the terminal compart-
ment along with all common cables of all electric valves.
The cables of the 24 Vac electric valves have no polarity. Connect the sensor wires to two cables in
output SENSOR. For version INDOOR connect transformer's cables to the 24-vac input.
20
SPA
Cavo 24 vac
Elettrovalvola
zona 1
Elettrovalvola
zona 2
Elettrovalvola
zona 3
Elettrovalvola
zona 4
Filo comune