Other equipment
Other equipment shall be mounted as described in the documentation following the
equipment.

Wiring

Wiring guidelines
Do not:
Make sharp bends in the cables.
Run cables in a way that allows water to flow down into the connectors.
Run the data cables adjacent to radar, transmitter, or large/high current carrying cables or
high frequency signal cables.
Run cables so they interfere with mechanical systems.
Run cables over sharp edges or burrs.
Do:
Make drip and service loops.
Use cable-tie on all cables to keep them secure.
Solder/crimp and insulate all wiring connections if extending or shortening the cables.
Use suitable crimp connectors or solder and heat shrink when extending cables. Keep joins as
high as possible to minimize possibility of water immersion.
Leave room adjacent to connectors to ease plugging and unplugging of cables.
Warning:
!
Before starting the installation, be sure to turn electrical
power off. If power is left on or turned on during the installation, fire,
electrical shock, or other serious injury may occur. Be sure that the voltage
of the power supply is compatible with the unit.
Warning:
!
The electrical wiring, connections and installation shall be
in accordance with the requirements of ISO 10133, ABYC E-11, AC or DC
electrical system on boats.