Technical Specifications; Egon+ Board - Simrad Naviop Loop M User Manual

Table of Contents

Advertisement

5
30 |

Technical Specifications

Egon+ board

Warning:
IGNITION PROTECTED ONLY WHEN EQUIPPED WITH
!
IGNITION PROTECTED FUSES AND COVER CLOSED.
ANY REPLACEMENT FUSES MUST BE IGNITION PROTECTED. COVER
MUST BE CLOSED IN EVERY OPERATIONAL CONDITION!
Environmental
Operating temperature -40°C to 85°C
Storage temperature -40°C to 125°C
Mechanical shock SAE J2030 (RDEC2002), Section 6.16
Bombardment test 24 hour of dust, sand and gravel
Protection class IP 66
Chemical resistance Break fluid, AT fluid, antifreeze fluid, windshield
Electrical
Power supply voltage 12 V DC (8-16 V DC)
Dielectric voltage withstanding 80 V DC
Current consumption 1.5 mA battery quiescent current
Total current limit 200 A
Total current limit per connector 100 A
Temperature rise 60°C
Insulation resistance 10 MOhm
Relay and fuse channels 20 A (resistive load)/16 A (inductive, motor,
Maximum board load 200 A
Power connector 2x M8 input studs, each rated at 100 A
Output wire size 1.31 mm2 - 5.26 mm2 (#10-16 AWG)
Abnormal conditions
Revers polarity protection - 24 V DC, SAE J1455 (RJUN2006) - duration of 5
Short circuit protection
Short to 16 V DC 5 minutes, ER455 (R2008) Section 5.10.4
Power up operation Ramp battery voltage from 0 to minimum
Technical Specifications |
Loop M User Manual
Salt fog 96 hour period of salt fog per ASTM B117-94
Vibration SAE J1455 (R2006), Section 4.10.4.2
wash fluid, PS fluid and oil.
Overload 135%
Max load
Fuse channels 30 A at 12 V DC
pump load) at 12 V DC
maximum
Power wire size Calculated based on total board consumption
Fuses Mini blade fuse
Relays 280 footprint, 4 pin relay
minutes
Short to ground 5 minutes, ER455 (R2008) Section 5.10.4
operating voltage ad 1 V/ms, EP455 (R2008)
Section 5.10.7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Naviop loop m+

Table of Contents