5.18 Setting pump post-circulation

The pump, in heating mode, is set for a
post-circulation of about one minute at the
end of each heat request.
This time can be changed from a minimum
of 10 seconds to a maximum of 20 minutes in
programming mode, using either the control
panel or the remote.
• Enter "programming mode" by pressing the
13 and 15 keys simultaneously for 5 seconds
(Figure 5.43) until HiS (Boiler History) ap-
pears on the LCD display (Figure 5.44).
12
13
Figure 5.43
- 48 -
INSTALLATION
to change the val-
mode (Figure 5.42).
17
16
15
14
Figure 5.44
• Scroll through the various menus by press-
ing the keys 13 (back) or 15 (forward), until
PAr (Parameters menu) appears on the LCD
display (Figure 5.45).
• Press the 14 key for 1 second to enter the se-
lected menu.
Figure 5.45
• Scroll through the various parameters by
pressing the keys 13 (back) or 15 (forward),
until P12, which alternates with the parame-
ter value, appears on the LCD display (Figure
5.46).
Figure 5.46
• Press the 14 key for 1 second (Figure 5.43)
to enter the selected parameter. The display
will show the following (Figure 5.47).