use electric cables with a cross section of no
less than 0.50 mm
2
.
The electrical conductors for connecting
the external sensor to the boiler must go
through different channels to those for the
mains voltage (230 V), as they are supplied
at a safe low voltage and cannot exceed 20
metres in length.
Use the terminals indicated in Figure 5.22 to
connect the external sensor.
The path of the external probe connection
wires must follow the path indicated in Figure
5.22.
Make the boiler cables exit using specific cable
glands R (Figure 5.24).
5.15 Selecting the type of external
sensor
The boiler is set to operate without an external
sensor.
If an external sensor (optional) IS CONNECT-
ED to the boiler, the correct parameter must
be set according to the type of probe installed.
Sequence for setting the type of external
sensor
• Enter "programming mode" by pressing the
13 and 15 keys simultaneously for 5 seconds
(Figure 5.25) until HiS (Boiler History) ap-
pears on the LCD display (Figure 5.26).
12
13
Figure 5.25
- 44 -
INSTALLATION
17
16
15
14
Figure 5.26
• Scroll through the various menus by press-
ing the keys 13 (back) or 15 (forward), until
PAr (Parameters menu) appears on the LCD
display (Figure 5.27).
• Press the 14 key for 1 second to enter the se-
lected menu.
Figure 5.27
• Scroll through the various parameters by
pressing the keys 13 (back) or 15 (forward),
until P57, which alternates with the parame-
ter value, appears on the LCD display (Figure
5.28).
Figure 5.28
• Press the 14 key for 1 second (Figure 5.25)
to enter the selected parameter. The display
will show the following (Figure 5.29).