SERVICE
This section provides procedures for testing and
replacing various major components used in this
brewer should service become necessary. Refer to
Troubleshooting for assistance in determining the
cause of any problem.
WARNING - Inspection, testing, and repair of electrical
equipment should be performed only by qualified ser-
vice personnel. The brewer should be unplugged when
servicing, except when electrical tests are required and
the test procedure specifically states to plug
in the brewer.
COMPONENT ACCESS
WARNING - Disconnect the brewer from the power
source before the removal of any panel or the replace-
ment of any component.
All components are accessible by the removal of
the top cover and front inspection panel and warmer
assemblies.
The top cover is attached with one #4-40 screw.
The front inspection panel is attached with four
#6-32 screws.
The warmer assembly is attached with three #4-40
screws.
Control Thermostat ............................................ 10
Limit Thermostat ................................................ 11
ON/OFF Switch ................................................... 12
Tank Heater ........................................................ 13
Tank Heater Switch ............................................ 14
Warmer Elements............................................... 16
Wiring Diagrams ................................................ 17
FIG. 1 COMPONENT ACCESS