3. Ensure the Frequency control is positioned at setting #7 (which is the factory default of 30 Hz).
Set Frequency control to setting #7.
4. On the front of the ionizer, ensure that air is blowing out from each of the nozzles.
Each nozzle blows air (polarized ions).
Verify ESD Elimination
5. Use an ESD field meter to measure the amount of ESD voltage present in the PSV7000 workspace
without (and with) the ionizer running. ESD readings with ionizer running should be near zero.
ESD near zero with ionizer running.
PSV7000 Ionizer Kit
16 |
P a g e
Need help?
Do you have a question about the PSV7000 and is the answer not in the manual?
Questions and answers