B46TU/B48TUEngines
3.CoolingSystem
3.3.4.Maximumcoolingrequirement
ThemaximumcoolingrequirementisshownatpointEoftheheatmanagementmodulecircuit
diagram.
Maximumcoolingrequirement
Toprovidemaximumcoolingathighdynamicloadsand/orhighambienttemperatures,theradiator
connectionisfullyopened(100%)andthebypasslineiscompletelyclosed.Additionally,theheater
circuitis90%closedtoachievethemaximumcoolingthankstothemaximumcoolantvolumetricflow
throughthelargecoolantcircuit.
25