Mercado Medic REAL 9000 PLUS Series Instructions For Assembly, Use & Care

Mercado Medic REAL 9000 PLUS Series Instructions For Assembly, Use & Care

Advertisement

Quick Links

REAL 9000 PLUS is a Class I medical device. It is CE marked in accordance with the Swedish Medical Products
Agency's code of statutes for medical devices, LVFS 2003:11, and has been tested and approved in accordance with
EN 1335, IEC 60601 and EN 12182. All textiles used in the chair have been tested and approved in accordance with
EN 1021-1 and EN 1021-2. Mercado Medic AB is certified to ISO 9001, ISO 14001 and ISO 13485 and complies with
applicable labour and environmental legislation.
If you have any questions about your product or if something unexpected has happened, please contact your dealer
first, otherwise you are welcome to contact us at Mercado Medic AB.
PDF versions of our instructions for use and care with magnification options can be found on our website:
www.mercado.se. Information is also provided on the website about accessories that can be installed on Mercado
Medic's chairs, as well as any field safety notices, prescribing support or recalls of products and accessories.
We reserve the right to make changes to this manual and its contents.
YOUR REAL® 9000 PLUS
† Adult
† Child/Mini
† Coxit
Sufficient competence in the safe use of this product is achieved by carefully reading
through these instructions for use and care before using the chair for the first time.
REAL
INSTRUCTIONS FOR ASSEMBLY, USE & CARE
REAL 9000 PLUS/EL/ADULT/CHILD/MINI/COXIT
† Manual
† El 24V
9000 PLUS SERIES
®

TABLE OF CONTENTS

Assembly for use . . . . . . . . . . . . . . . . . . 2
Familiarise yourself with REAL 9000
PLUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Expected service life . . . . . . . . . . . . . . . 4
Cleaning & care . . . . . . . . . . . . . . . . . . . . 4
Instructions for destruction . . . . . . . . . 4
Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Reconditioning and service . . . . . . . . . . 5
Individual adaptation . . . . . . . . . . . . . . . 7
User manual . . . . . . . . . . . . . . . . . . . . . . 8
Brake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Seat tilt (option) . . . . . . . . . . . . . . . . . . . 8
seat tilt backwards (Option) . . . . . . . . . 9
Backrest mechanism . . . . . . . . . . . . . . . 9
Armrests . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Setting the coxit flaps . . . . . . . . . . . . . . 10
Rotation release (Option). . . . . . . . . . . 10
Charging . . . . . . . . . . . . . . . . . . . . . . . . . 10
Charging, Cont. . . . . . . . . . . . . . . . . . . . 11
Doc. no: 20-06352-UK-03
Art. no:
804838
Amended
2020-12-04
Valid from
2017-06-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the REAL 9000 PLUS Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mercado Medic REAL 9000 PLUS Series

  • Page 1: Table Of Contents

    EN 1335, IEC 60601 and EN 12182. All textiles used in the chair have been tested and approved in accordance with EN 1021-1 and EN 1021-2. Mercado Medic AB is certified to ISO 9001, ISO 14001 and ISO 13485 and complies with applicable labour and environmental legislation.
  • Page 2: Assembly For Use

    ASSEMBLY FOR USE Brake lever Armrests Remove the chair from the cardboard box. Place the Loosen the controls for the armrest (2). Set the brake lever in the brake lever bracket (1) on the right or desired level in height and width. Tighten all left side.
  • Page 3: Plus

    Mercado Medic AB. To maintain the CE marking, modifications or changes must not be carried out without Mercado Medic AB’s approval. Repairs and other technical measures may only be carried out by personnel authorised by Mercado Medic AB.
  • Page 4: Expected Service Life

    After the expected service life, Mercado Medic AB cannot guarantee the suitability and safety of the product, as Mercado Medic AB has no control over how the product has been used and wear and tear. The overall...
  • Page 5: Symbols

    SYMBOLS 6. Warning! Read the manual 1. Seat height up/down. before use. 2. Seat tilt forewards/ 7. Charging connection. backwards. 24VDC 8. Separation of source materials 3. Back recliner forwards/backwards. 9. The product is part of a recycling process. 4. Activate/release brake. 10.
  • Page 6 The electric lifting mechanism can be Make sure that guide bushings and … 8.4. Armrest mechanics / function sent to Mercado Medic AB for repair/ plastic plugs are properly secured, and Check all welds and that there is no reconditioning.
  • Page 7: Individual Adaptation

    Mercado Medic AB for written approval. Parts to be evaluated must be sent physically to Mercado Medic AB, either by the customer or the supplier of the part in question. Mercado Medic AB will then contact the supplier of the part in question; if a combination agreement is deemed to be of interest, Mercado Medic AB performs a risk analysis on the part.
  • Page 8: User Manual

    BRAKE USER MANUAL  Controls NOTE! The brake on the chair must always be applied when getting in and out of the chair. The brake must be 1. Brake, PLUS base 48 move lever forward checked on a regular basis. In case of wear, change the 2.
  • Page 9: Reversed Seat Tilt Or Full Seat Tilt Backwards (Option)

    REVERSED SEAT TILT OR FULL SEAT TILT BACKWARDS (OPTION) Controls 1. Armrest placed here follows the seat tilt 2. Armrest placed here does not follow the seat tilt 3. There are 3 positions. When position 3 is chosen, the chair must be fitted with a base extender 1.
  • Page 10: Setting The Coxit Flaps

    Mercado Medic AB, the CE marking and Mercado Medic AB’s product liability will cease to be valid for any cases regarding the battery, charging or other electronics of the chair. The battery should be charged on a daily basis. Fully charging the battery on a daily basis will take 2-6 hours.
  • Page 11: Charging, Cont

    If none of the above measures are able to resolve the problem, servicing may be required. Please contact your dealer or get in touch with Mercado Medic AB. You will find our contact details on the last page of this manual.
  • Page 12 Mobile phone: +46 (0)70-550 63 98 Fax: +46 (0)8-555 143 99 +46 (0)70-894 63 68 E-mail: service@mercado.se E-mail: info@mercado.se [Space for product label with serial number.] Mercado Medic AB Telephone & Fax E-mail & Internet Tryffelslingan 14 Tel. +46 (0)8-555 143 00 E-mail info@mercado.se...

Table of Contents