Bunn Single TF Operating & Service Manual page 37

1.75 gallon
Table of Contents

Advertisement

SERVICE (cont.)
TANK HEATER (cont.)
Electronic Control Models:
1.
Disconnect the brewer from the power source.
2.
Disconnect wires from heater.
3.
Check for continuity across the tank heater ter-
minals.
If continuity is present as described, the tank heater is
operating properly.
If continuity is not present as described, replace the
tank heater.
NOTE - If the tank heater remains unable to heat,
remove and inspect the heater for cracks in the sheath.
BLK to Contactor T2
RED to Contactor T1
ELECTRO/MECHANICAL
Removal and Replacement:
1.
Remove wires from tank heater.
2.
Remove the four #8-32 nuts securing tank heat
to tank lid.
3.
Remove tank heater and gasket.
4.
Install new tank heater and gasket with four #8-
32 nuts on tank lid.
5.
Refer to the illustration below when reconnect-
ing the wires.
ELECTRONIC
Page 37
BLK to Limit Thermostat
BLU Lead from
Triac Assy
P837
27118 100400

Advertisement

Table of Contents
loading

Table of Contents