Bunn Single TF Operating & Service Manual page 19

1.75 gallon
Table of Contents

Advertisement

SERVICE (cont.)
CONTACTOR ASSEMBLY (W/ MECHANICAL THER-
MOSTAT ONLY) (cont.)
If continuity is present as described, the contactor is
operating properly.
If continuity is not present as described, replace the
contactor.
Removal and Replacement:
1. Remove all wires from the contactor.
2. Remove the two #10-32 slotted head screw secur-
ing contactor to the inside of the hood.
3. Securely install the new contactor inside the hood.
4. Refer to the illustration below when reconnecting
the wires.
P828
Page 19
27118 100400