Savant CLI-W210 Deployment Manual

Multistat smart thermostat
Hide thumbs Also See for CLI-W210:

Advertisement

Multistat Smart Thermostat Deployment Guide
Document Number:
009-1959-00
Document Date:
July 2020
Document Supports:
CLI-W200x - da Vinci 8.8 and higher
CLI-W210x - da Vinci 8.8.2 and higher
This guide will assist the installer/integrator through the installation, wiring, and initial configuration of the Multistat Smart Thermostat.
Copyright © 2020 Savant Systems, Inc.
1 of 21
45 Perseverance Way, Hyannis MA 02601
Savant.com
| 508.683.2500

Advertisement

Table of Contents
loading

Summary of Contents for Savant CLI-W210

  • Page 1 CLI-W210x - da Vinci 8.8.2 and higher This guide will assist the installer/integrator through the installation, wiring, and initial configuration of the Multistat Smart Thermostat. Copyright © 2020 Savant Systems, Inc. 1 of 21 45 Perseverance Way, Hyannis MA 02601 Savant.com...
  • Page 2: Table Of Contents

    Basic Configuration Using the On-Screen Menus ......................................16 Appendix A: HVAC Data Table Basics ............................................19 Appendix B: Network Requirements ............................................. 20 Multistat Smart Thermostat Deployment Guide (CLI-W210x/W200x) 2 of 21 45 Perseverance Way, Hyannis MA 02601 009-1959-00 | 200723 Savant.com | 508.683.2500...
  • Page 3 Important Safety Information - Read First Safety Statements Before installing, configuring, or operating any equipment and other, Savant All safety instructions below should be read, understood, and applied under all recommends that each dealer, integrator, or installer, access and read all the relevant circumstances when working with this equipment.
  • Page 4: Before You Begin

    Multistat Smart Thermostat and Hardware ........................................... Savant Control System running da Vinci 8.8 or higher ......................................HVAC system installed and appropriate wires run to the thermostat’s location(s) ............................
  • Page 5: Related Documentation

    When complete, the thermostat will be ready to add to a Savant Pro System. – Pro App HVAC Service User Guide (009-1542-xx) - Once added to a Savant system, this guide contains the information needed to work in the HVAC Service in the Savant Pro App.
  • Page 6: Wiring Diagrams

    – Connect Y1 from the thermostat to Y1 (stage 1 cooling) in the HVAC system. system. – Savant recommends using standard #18 AWG HVAC wiring. – Connect G from the thermostat to the fan terminal in the HVAC system. –...
  • Page 7 Connect the Y1 terminal on the thermostat to Y1 in the HVAC system. system. – Connect theY2 terminal on the thermostat to Y2 in the HVAC system. – Savant recommends using standard #18 AWG HVAC wiring. – Connect the G terminal on the thermostat to the fan in the HVAC system. –...
  • Page 8 Connect the O terminal on the thermostat to the changeover/ reversing valve on the heat pump. reversing valve on the heat pump. – Savant recommends using standard #18 AWG HVAC wiring. – Savant recommends using standard #18 AWG HVAC wiring. Multistat Smart Thermostat Deployment Guide (CLI-W210x/W200x)
  • Page 9 – Savant recommends using standard #18 AWG HVAC wiring. HELPFUL! Taco zone valves were used in the diagrams above. When wiring a different type of zone valve, refer to the documentation for that valve. Multistat Smart Thermostat Deployment Guide (CLI-W210x/W200x)
  • Page 10 W1, W2, or O to complete the circuit. When connecting the transformer to the RC connection, use either Y1, Y2, – Savant recommends using standard #18 AWG HVAC wiring. or G (see diagram above). – Savant recommends using standard #18 AWG HVAC wiring.
  • Page 11 The CLI-THFM1 is the only 1-Wire sensor supported. – Five hundred feet (152 m) is the maximum distance supported. Savant recommends a #24 AWG or larger twisted pair. – Six hundred feet (182 m) cumulative is the maximum cable length supported for the 1-Wire sensor.
  • Page 12 With one power source in the system, the hot wire from the transformer is wired to RC. See the Connect Power - One Transformer used to power the HVAC system section in the Multistat Smart Thermostat Quick Start Guide that is available on the Savant Community.
  • Page 13: Add Thermostat To A Blueprint Configuration

    Close the component library (Hide Library from the Blueprint toolbar). D 1.31 Double click the thermostat and open its inspector. 10. Enter the 16-character UID into the Savant UID field (see image to the right). – The UID is printed on a sticker on the electronics board for...
  • Page 14: Save Configuration, Generate Services, And Upload File

    6. Save Configuration, Generate Services, and Upload File With the thermostat profile added to the Blueprint configuration complete, the file can now be uploaded to the Savant Host. Select the Generate Services icon from the Blueprint toolbar to update the realized services with the configuration changes. When using TrueControl II interfaces within a config, select Update All UI Screens to sync with services.
  • Page 15: Wi-Fi Network

    If the thermostat is reset to factory defaults, the IP information is lost and the thermostat will need to be reconnected to Wi-Fi. – Once provisioned to a network with WAN access, the thermostat will query the Savant Cloud and initiate a firmware download when an updated version is available.
  • Page 16: Basic Configuration Using The On-Screen Menus

    This section details the on-screen menus that are available using the thermostat's touchscreen. Use the descriptions below when configuring HVAC control. Note that Savant recommends connecting the device to the local Wi-Fi network before proceeding. While connection to a network is not required, some features relying on Internet connectivity are unavailable for devices not provisioned to Wi-Fi.
  • Page 17 NEXT like the CLI-THFM1 provides the indoor temperature. The label on the button is the UID of the sensor. Multistat Smart Thermostat Deployment Guide (CLI-W210x/W200x) 17 of 21 45 Perseverance Way, Hyannis MA 02601 009-1959-00 | 200723 Savant.com | 508.683.2500...
  • Page 18 SKIP SKIP code. Use the information below to edit the Weather ON - Global / Shared Scenes from the local Savant Settings screen. SELECT HOST Host (Select Host below) are made accessible from...
  • Page 19: Appendix A: Hvac Data Table Basics

    Appendix A: HVAC Data Table Basics The HVAC data table in Blueprint affects what functions and features are available in the Savant Pro and TrueControl II apps. Modifications made to the data table will affect what functions and features are available in these apps. An explanation of each field in this table is described below.
  • Page 20: Appendix B: Network Requirements

    Network Changes Savant recommends performing the following to refresh the IP connection after connecting to a new network, changing routers, or if the IP address range is changed in the current router. This will reset any IP connection and ensure that the device is communicating with the network correctly.
  • Page 21 Savant Systems, Inc. shall not be liable for any technical or editorial errors or omissions contained herein or for incidental or consequential damages resulting from the performance, furnishing, reliance on, or use of this material.

Table of Contents