IMPORTANT SAFETY INSTRUCTIONS When using this electrical equipment, basic safety pre- cautions should always be followed, including the follow- ing: READ AND FOLLOW ALL • INSTRUCTIONS • Disconnect all AC power during installation. • Warning - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
INSTALLATION Mounting..................9 nauthorized repairs or of natural stone used in Plumbing..................10 E CONSTITUTE THE Wiring..................11 NTIFIED HAYWARD/ ODUCTS AND IS IN , INCLUDING WAR- ICULAR PURPOSE. TROUBLESHOOTING AND YOU MAY ALSO REVENUE, COSTS EXPENSES, EVEN IF Troubleshooting................13...
Operation control unit and th 12" of straight pipe still on, check that The Aqua Trol is an automatic chlorine generation system with a built-in filter direction of flow. ® pump timer designed specifically for above ground pools. The operation requires "Test Sal a low concentration of salt (sodium chloride) in the pool water at levels low enough Take a sample of y...
Page 5
Water Chemistry As with any pool, it is important that you maintain chemical makeup of the pool water. The table on page 2 summarizes the levels that are recommended by the National Spa and Pool Institute (NSPI). The only special requirement for the Aqua Trol is the salt level and stabilizer.
Page 6
It is important to use only sodium chloride (NaCl) that is 99% pure. This is common to GFCI receptacl food quality or water softener salt available in 40-80 lb. bags at your local Hayward/ Goldline dealer. It is also acceptable to use water conditioning salt pellets, how- ever, it will take longer for them to dissolve.
Page 7
ny wiring. Be sure as been designed to safe operation, the POUNDS and (Kg) OF SALT NEEDED FOR 3200 PPM Gallons and (Liters) of Pool/Spa water into a GFCI recep- ceptacle wired to a Current salt level circuit protected by 6,000 8,000 10,000...
Page 8
Plumbing The cell and flow s Stabilizer (Cyanuric Acid the pool. Install aft The kit included in Always check stabilizer (cyanuric acid), when checking salt. These levels will most either 2" (51mm) ri likely decline together. Use the chart below to determine how much stabilizer must installation.
Controls EC codes. Timer The pool filter pump should run long enough to circulate the entire volume of pool water each day. This will vary depending on pump size, pool plumbing and pool size. Consult a local pool store to help determine the appropriate run time for your chemistry must be pool.
Page 10
Maintaining th NO FLOW When illuminated, the flow switch has detected no flow and the Aqua Trol ® has stopped generating chlorine. A flashing LED indicates a 15/60 second To maintain maximu time delay period. inspect the cell ever remind you to do this TEST SALT LEVEL When flashing, the salt level is low (below 2700ppm) and hours of operation.
Maintaining the Aqua Trol ® System no flow and the Aqua cates a 15/60 second To maintain maximum performance, it is recommended that you open and visually inspect the cell every 3 months or after cleaning your filter. The Aqua Trol will remind you to do this by flashing the "Inspect Cell"...
Installation Controls Installation must be performed in accordance with Local and NEC codes. Timer The pool filter pum Preparing Pool Water water each day. T size. Consult a loc Refer to page 2 for recommended chemical levels. The pool's chemistry must be pool.
Plumbing The cell and flow switch (not used on -RJ systems) are plumbed in the return line to the pool. Install after (downstream) all the pool equipment (filter, heater, solar, etc.). The kit included in the Aqua Trol provides the necessary plumbing components for ese levels will most either 2"...
Wiring Power must be shut off at the circuit breaker before performing any wiring. Be sure to follow Local and NEC/CEC electrical codes. The Aqua Trol has been designed to easily wire into typical above ground pool systems. To provide safe operation, the Aqua Trol must be properly grounded and bonded.
Page 15
Bonding lug to 120 VAC linecord e. This is common to pool pump pool bonding system to GFCI receptacle/breaker our local Hayward/ salt pellets, how- alt, salt with more -caking additives, Brush the salt to pile on the bottom ming from the main...
Water Chem Troubleshooting As with any pool water. The table National Spa and Trol is the salt lev Diagnostic Displays to prevent corros Test your water Sequential pushes of the small "diagnostic" button next to the LCD display will chemicals and pr cause the Aqua Trol to display the following information: store that you are 1.
Page 17
control unit and that the wire is not cut or damaged. Make sure you have at least 12" of straight pipe before the flow switch. If there is adequate flow and the LED is still on, check that the arrows on the flow switch (on top of hex) are pointing in the ith a built-in filter direction of flow.
SwimPure chlorination products to be free of defects in materials and workmanship, under normal use and service, for a period of three (3) years. Hayward/Goldline also warrants its Aqua Trol chlorination products to be free of defects in materials and workmanship, under normal use and service for a period of one (1) year.