Prestige medical Anima User Manual

Prestige medical Anima User Manual

Vacuum & non-vacuum autoclave

Advertisement

User Manual
Vacuum &
Non-Vacuum Autoclave
www.dlc.com.au

Advertisement

Table of Contents
loading

Summary of Contents for Prestige medical Anima

  • Page 1 User Manual Vacuum & Non-Vacuum Autoclave www.dlc.com.au...
  • Page 2: Table Of Contents

    Service Helpline: Telephone: 01254 844 116 Operation Essential Information e.mail: customerservice@prestigemedical.co.uk Routine Care and Maintenance Prestige Medical Service staff are available to provide advice and assistance during normal office hours. To avoid Trouble Shooting delays when making contact please have the unit’s Model Recovery Sequences and Serial Numbers at hand.
  • Page 3: Introduction

    Section 1: Introduction Thank you for choosing the Prestige Medical Anima Types of load and loading. autoclave. This autoclave has been qualified to sterilize loads as defined by EN13060. The door remains closed throughout the cycle, including drying. Cycles P1 & P2 – Wrapped, pouched, solid, hollow instruments (length to diameter ratio 750:1 Length may be An “Auto-cycle start”...
  • Page 4: Operating Symbols, Displays And Controls

    Section 2: Operating Symbols, Displays and Controls Pouched instruments should be placed on pouch trays for best drying results Do not use an unprotected hand to hold hot trays. Fill water tank when Do not use tap water IMPORTANT: Read Hot parts.
  • Page 5: Operation

    Section 3: Operation Cycle controls. Press G to select the vacuum cycles these are as follows: Please take time to read these instructions 134°C/3min.20sec Vacuum cycle before using the autoclave. It is essential that the for porous loads, wrapped, pouched, operator is correctly trained and a “Responsible solid / hollow instruments, with 25 Person”...
  • Page 6 Place on a heat resistant surface whilst emptying the 7. Loading. container. Refer to “Type of load and loading” on page 3 “Specifications” on page 15 for the maximum permissible Use the carry handle to support the container when emptying. load.
  • Page 7 (D) up and (E) down. Accept by pressing button (F). A Bowie Dick Test Pack or a Test Helix MUST be used with this test (available from Prestige Medical). • The unit returns to “Ready Mode” and the LED to the The Pack or Helix should be placed on an instrument left of the clock symbol continues to flash.
  • Page 8: Essential Information

    Section 4: Essential Information To ensure the autoclave continues to operate correctly Do not…. it is important to follow the following points and to carry …lose this handbook. out the necessary care and maintenance procedures as …lose this handbook. specified. …add any chemicals whatsoever to the water.
  • Page 9: Routine Care And Maintenance

    Section 5: Routine Care and Maintenance Should the gasket develop a persistent leak it should be WARNING! removed, cleaned thoroughly in warm soapy water and Disconnect the autoclave from the mains power shaken dry. Wiping with a lint-free cloth is acceptable supply before cleaning.
  • Page 10: Trouble Shooting

    As non-warranty related calls can be expensive it is advisable to ensure that all consumable items have been replaced or cleaned as appropriate, and that the water quality is as described in Section 13 before contacting Prestige Medical Ltd. 304278B...
  • Page 11: Recovery Sequences

    Section 7: Recovery Sequence (allows instruments to be removed from the unit). Recovery Sequence (allows instruments to be removed from the unit). Recovery Sequence “i” Recovery Sequence “ii” Recovery Sequence “iii” Press button (A) Press button (A) Press button (A) Stabilize (no flashing or bleeping) Stabilize (no flashing or bleeping) Stabilize (no flashing or bleeping)
  • Page 12: Additional Information

    NOTE Always drain the water tank before Test Pack (Part No.309031) moving. Before moving always allow 30 minutes after use for the unit to cool down. Prestige Medical Ltd approved TST Helix available from: Albert Browne Ltd. Cleaning Materials: Leicester Mild washing up liquid.
  • Page 13: Warranty

    Warranty Section 10: Printer Instruction (Optional) Prestige Medical Ltd will, in the first twelve months from the date of purchase (or 18 months from the date of Power on procedure factory despatch – whichever is first), repair or replace free...
  • Page 14: Technical Specification

    Section 11: Technical Specification Chamber component materials. Mains plug top fuse (user replaceable) F13A to BS1362 UK only. Vessel: Stainless Steel – 304 –S15 Boiler: Aluminium – LM25 Maximum single fault temperature: Lid: Aluminium – ASME SB26 356.0 T6 143ºC determined by the pressure release valve. Door Plate: Stainless Steel –...
  • Page 15: Water Quality

    Section 12: Water Quality Must be suitable to produce steam in accordance with international standards. Example specification for clean steam Determinant Value Recommended test for compliance Based on Sterilized Water for Injections BP: Acid or Alkalinity. BP test. Tests for pH are not an acceptable substitute.
  • Page 16: Daily Record Sheet

    Section 14: Daily Record Sheet L OAD TYPE. CYCLE DATE CYCLE NUMBER PASS OR FAIL * OPERATOR (See KEY below) SELECTED. KEY FOR LOAD B = Hollow P = Pouched U = Unwrapped M = Mixed TYPES: - Instruments or bagged Instruments Instruments *If a cycle fails record the Error Code in the Pass/Fail column...