Before testing, the system should be disarmed and all protected doors and windows closed. The
Home button should show green.
No alarm messages are sent to your alarm monitoring company during these tests.
Press Tools and enter the 4-digit Master User code. Press Advanced.
Testing Sensors
Home > Security > Tools > Advanced > Walk Test
Start by pressing Walk Test.
The Gateway's internal sounder loudly sounds and Walk Test – Home to Quit appears. The
Gateway
then beeps every 30 seconds as a reminder that the system is in Test mode.
Note that Walk Test mode automatically quits after 4 hours.
Doors and Windows
Motion Sensors
Fire/Carbon Monoxide
sensors
When testing smoke detectors, keep the Lyric
least one minute (60 seconds) after testing the detector to avoid sending
unwanted alarm messages to your central station monitoring company.
If there is a problem with any sensor (no confirming sounds, no display), notify your service
company.
When all sensors have been checked (and doors and windows closed), no zone identification
numbers should be displayed.
Finish by pressing Home and entering the Master User code.

Testing Your System

NOTE: TESTING SHOULD BE PERFORMED WEEKLY.
(Walk Test)
Open each protected door and window in turn and listen for three
beeps from the Gateway. If programmed to do so, each zone's voice
descriptor is heard. Identification of protection points with problems
should appear on the display
Notifications of problem zones clear when the door or window is
closed.
Walk in front of each sensor and listen for three beeps and/or voice
descriptors.
The device's identification should appear on the display when it is
activated. The display clears when no motion is detected.
NOTE: If wireless motion detectors are in use, there is a 3-minute
delay between activations, which helps preserve battery life.
Follow the manufacturer's instructions to test these devices. When a
device is activated, its identification should appear on the touch
MyHome Gateway App
MyHome Gateway App
screen.
IMPORTANT
Gateway
46
screen.
in test mode for at

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lyric lcp300-lc

Table of Contents