Pro Series System
Menus (continued)
P
S
Si-1750 M
ro
erieS
anual
MENU 10: MISS
If your feeder is equipped with the Systems Interface I/O option, this
menu will allow you to activate the Miss Output and configure its
operation as follows:
1. Output: OFF/ON
2. Duration: 20mS to 999mS (Default is 100mS)/0 LATCHED
3. Feeder Pause: OFF/ON
To energize the output if a Miss occurs:
1. Use the Up/Down Arrow keys to position the cursor arrow by
Output.
2. Press the Enter key. This will take you to a submenu where you
will choose either Consecutive Misses OR Average Misses:
Consecutive Misses: (1-99)
1. Press the Enter key to engage the cursor. Use the Up/Down keys
or numeric keypad to set your desired number of misses before
an output signal is generated. (A value of 1 indicates that no
misses are acceptable; a value of 2 indicates that 1 miss is ac-
ceptable but 2 in a row is not, etc.)
2. Press Enter to save new value or press Menu to restore old
value.
3. Press the Menu key to bring you up a level, out of the submenu
and back to the Miss primary screen.
4. Verify that Output is ON.
To set the length of time the Miss Fault output will be energized in the
event of a miss:
1. Use the Up/Down Arrow keys to position the cursor arrow by
Duration.
2. Press the Enter key to engage the cursor.
3. Use the Up/Down keys or numeric keypad to set your desired
value. (20mS to 999mS). However, you may enter a value of
zero. This will cause the Miss Output to latch "On" in the event
of a Miss. The Miss Fault output will remain latched until the
next Flight Trigger is received.