Thiele Streamfeeder Pro Series Manual page 38

Table of Contents

Advertisement

Visual Inspection
(continued)
31
Replacing Worn Angled Wedge
To replace a worn angled wedge:
1. Turn Off feeder and remove power cord from outlet.
2. Remove gate assembly from gate plate.
3. Use a pliers to grip and remove angled wedge.
4. Install new wedge by inserting one end and then pushing in
until centered. Do not grip new wedge with pliers as this may
cause damage to the edge.
5. Reinstall gate assembly and restore power.
Standard O-Ring Gate: Adjusting Worn
O-Rings
To adjust worn O-rings on standard O-ring gate:
1. Turn Off feeder and remove power cord from outlet.
2. Remove gate assembly from gate plate.
3. Insert a screwdriver in slot on top of gate assembly and rotate
screwdriver clockwise or counter-clockwise 360° so as to
move worn area of O-ring about 1/8 to 1/4 in. (3 to 6 mm).
4. Remove screwdriver and repeat for each ring as necessary.
5. Reinstall gate assembly and restore power.
Advancing O-Ring Gate: Adjusting Worn
O-Rings
To adjust worn O-rings on advancing O-ring gate:
1. Turn Off feeder and remove power cord from outlet.
2. Make sure advance knob is in-line with the side plate and
secure. Then loosen left and right locking wing nuts.
3. Rotate O-rings by grasping advance knob and pushing to-
wards gate cylinder about 1/8 to 1/4 in. (3 to 6 mm).
4. Retighten locking wing nuts. Then loosen advance knob and
move to original position (in-line with side plate). Retighten.
5. Reinstall gate assembly and restore power.