Ordering Data - FIP FLS F3.00.W Manual

Wireless paddlewheel flow sensor
Table of Contents

Advertisement

Correction formula for K-Factor calculation according to real internal
diameter:
K-Factor_NEW = (K-Factor x ID²) / ID_NEW²
ID = Value in the table for the internal diameter (in mm)
ID_NEW = New value for the real internal diameter (always in mm)
K-Factor = Value in the table
K-Factor_NEW = New K-Factor value for the specified internal diameter
Example:
Nominal Pipe Size (DN) = 100 mm
New Internal Diameter = 104 mm
Forumla: K-Factor_NEW = (51.02 x 100²) / 104² = 20,52

ORDERING DATA

Part No.
Version
F3.00.W.13
Hall
F3.00.W.14
Hall
F3.00.W.15
Hall
F3.00.W.16
Hall
F3.00.W.17
Hall
F3.00.W.18
Hall
F3.00.W.19
Hall
F3.00.W.20
Hall
F3.00.W.21
Hall
F3.00.W.22
Hall
F3.00.W.23
Hall
F3.00.W.24
Hall
Power
Length
supply
See electrical
L0
data section
See electrical
L0
data section
See electrical
L1
data section
See electrical
L1
data section
See electrical
L0
data section
See electrical
L0
data section
See electrical
L1
data section
See electrical
L1
data section
See electrical
L0
data section
See electrical
L0
data section
See electrical
L1
data section
See electrical
L1
data section
Main wetted
Enclosure
materials
CPVC/EPDM
IP65
CPVC/FPM
IP65
CPVC/EPDM
IP65
CPVC/FPM
IP65
PVDF/EPDM
IP65
PVDF/FPM
IP65
PVDF/EPDM
IP65
PVDF/FPM
IP65
316SS/EPDM
IP65
316SS/FPM
IP65
316SS/EPDM
IP65
316SS/FPM
IP65
Flow Rate
Weight
Range
(gr.)
0.15 to 8 m/s
750
(0.5 to 25 ft./s.)
0.15 to 8 m/s
750
(0.5 to 25 ft./s.)
0.15 to 8 m/s
800
(0.5 to 25 ft./s.)
0.15 to 8 m/s
800
(0.5 to 25 ft./s.)
0.15 to 8 m/s
750
(0.5 to 25 ft./s.)
0.15 to 8 m/s
750
(0.5 to 25 ft./s.)
0.15 to 8 m/s
800
(0.5 to 25 ft./s.)
0.15 to 8 m/s
800
(0.5 to 25 ft./s.)
0.15 to 8 m/s
950
(0.5 to 25 ft./s.)
0.15 to 8 m/s
950
(0.5 to 25 ft./s.)
0.15 to 8 m/s
1000
(0.5 to 25 ft./s.)
0.15 to 8 m/s
1000
(0.5 to 25 ft./s.)
19