Correction formula for K-Factor calculation according to real internal
diameter:
K-Factor_NEW = (K-Factor x ID²) / ID_NEW²
ID = Value in the table for the internal diameter (in mm)
ID_NEW = New value for the real internal diameter (always in mm)
K-Factor = Value in the table
K-Factor_NEW = New K-Factor value for the specified internal diameter
Example:
Nominal Pipe Size (DN) = 100 mm
New Internal Diameter = 104 mm
Forumla: K-Factor_NEW = (51.02 x 100²) / 104² = 20,52
ORDERING DATA
Part No.
Version
F3.00.H.01
Hall
F3.00.H.02
Hall
F3.00.H.03
Hall
F3.00.H.04
Hall
F3.00.H.05
Hall
F3.00.H.06
Hall
F3.00.H.07
Hall
F3.00.H.08
Hall
F3.00.H.09
Hall
F3.00.H.10
Hall
F3.00.H.11
Hall
F3.00.H.12
Hall
F3.00.H.13
Hall
20
F3.00.H.XX Paddlewheel Flow Sensors (Remote version)
Power
Length
supply
5 - 24 VDC
L0
5 - 24 VDC
L0
5 - 24 VDC
L1
5 - 24 VDC
L1
5 - 24 VDC
L0
5 - 24 VDC
L0
5 - 24 VDC
L1
5 - 24 VDC
L1
5 - 24 VDC
L0
5 - 24 VDC
L0
5 - 24 VDC
L1
5 - 24 VDC
L1
5 - 24 VDC
L0
Main
wetted
Enclosure
materials
CPVC/ EPDM
IP68
CPVC/FPM
IP68
CPVC/ EPDM
IP68
CPVC/FPM
IP68
PVDF/EPDM
IP68
PVDF/FPM
IP68
PVDF/EPDM
IP68
PVDF/FPM
IP68
316SS/EPDM
IP68
316SS/FPM
IP68
316SS/EPDM
IP68
316SS/FPM
IP68
CPVC/EPDM
IP65
Flow Rate
Weight
Range
(gr.)
0.15 to 8 m/s
250
(0.5 to 25 ft./s.)
0.15 to 8 m/s
250
(0.5 to 25 ft./s.)
0.15 to 8 m/s
300
(0.5 to 25 ft./s.)
0.15 to 8 m/s
300
(0.5 to 25 ft./s.)
0.15 to 8 m/s
250
(0.5 to 25 ft./s.)
0.15 to 8 m/s
250
(0.5 to 25 ft./s.)
0.15 to 8 m/s
300
(0.5 to 25 ft./s.)
0.15 to 8 m/s
300
(0.5 to 25 ft./s.)
0.15 to 8 m/s
600
(0.5 to 25 ft./s.)
0.15 to 8 m/s
600
(0.5 to 25 ft./s.)
0.15 to 8 m/s
650
(0.5 to 25 ft./s.)
0.15 to 8 m/s
650
(0.5 to 25 ft./s.)
0.15 to 8 m/s
250
(0.5 to 25 ft./s.)