Walrus Systemflo SLB-C Series Installation And Operation Manual page 6

Vertical multistage centrifugal pump
Table of Contents

Advertisement

SLB-C, SLB-S, SLB-N
Pos.
If it is necessary to increase the diameter of the suction pipe, place an eccentric reducer between the
8
check valve and the flexible pipe section.
Using elbows will increase the flow resistance. Wide bends will result in lesser flow resistance.
9
The piping must have a level or positive gradient to prevent the formation of air pockets.
10
The diameter of the drop pipe must be larger than the diameter of the pump's suction port.
11
Use a foot valve in case of negative suction head.
12
Size pump for correct head.
13
Place the intake of the suction pipe so that the intake is always submerged to prevent entry of air.
14
Install a compound gauge at the pump suction and a pressure gauge at the pump discharge.
15
Description