Advertisement

Quick Links

Customer:
Description:
Air Conditioner for Equipment
Customer Part No.:
Delta Model No.:
Sample Date Code:
Sample Issue Date:
DELTA ELECTRONICS, INC.
252, SHANG YING ROAD, KUEI SAN
TAOYUAN CITY 333, TAIWAN
Specification and Manual
HEC1000AFR
Please send one copy of this specification back after
you signed approval for production pre-arrangement
Approved by:
Date:
Rev.:
Rev.:
X00
TEL: 886-(0)3-3591968
FAX: 886-(0)3-3591991

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HEC1000AFR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Delta HEC1000AFR

  • Page 1 Specification and Manual Customer: Description: Air Conditioner for Equipment Customer Part No.: Rev.: Delta Model No.: HEC1000AFR Rev.: Sample Date Code: Sample Issue Date: Please send one copy of this specification back after you signed approval for production pre-arrangement Approved by: Date: DELTA ELECTRONICS, INC.
  • Page 2: Table Of Contents

    Part no.: Delta model no.: HEC1000AFR Table of content Description ............................3 Packing & Shipping ........................... 3 Safety Notes ............................3 Product Instruction ........................7 1-1. General Description ......................7 1-2. Main Feature & Model Number ..................7 1-3. Dimension ........................... 9 1-4.
  • Page 3: Description

    The document is the exclusive property of Delta Electronics, Inc. it should not be distributed, reproduced, or any other format without prior permission of Delta.
  • Page 4 Part no.: Delta model no.: HEC1000AFR Warning: Installation work and electrical wiring should be done only by qualified personnel in accordance with all applicable codes, standards and national wiring regulations. Use this unit only in the manner intended by the manufacturer. If you have questions, please contact the manufacturer.
  • Page 5 Part no.: Delta model no.: HEC1000AFR Caution : Install the air conditioner on a wall or door strong enough to withstand the weight of the unit. Do not allow a child to mount onto the outdoor unit. Avoid placing any object on it.
  • Page 6 Specification for Approval Customer : Description : Air conditioner for Equipment with 1000 W Rated Cooling Capacity Customer P/N : Rev. : Delta model no. : HEC1000AFR Rev. : 00 Sample revision. : Date Code : Sample issue date :...
  • Page 7: Product Instruction

    1. Product Instruction 1-1. General Description HEC1000AFR is a AC air conditioner with 115VAC power input, it is designed for NEMA4X sealed outdoor telecom cabinet to provide stable and optimum internal conditions for equipment and avoid hotspot inside the cabinet.
  • Page 8 Part no.: Delta model no.: HEC1000AFR Input Voltage Range 103~121/50Hz,105~127/60Hz Locked Rotor Current (60Hz) 15.9 Rated Current Minimum circuit ampacity (MCA) Maximum rating of overcurrent protective 11.7 device (MOP) Alarm Dry Contact Output Key Components Controller Built-in Smart Controller Fans...
  • Page 9: Dimension

    Part no.: Delta model no.: HEC1000AFR 1-3. Dimension mm(inch) (1) Material: SUS 304 (2) Finish: N/A (3) Color: N/A (4) Dimension tolerance: ± 1.0mm Page 9...
  • Page 10: Mounting Plane Cutout

    Part no.: Delta model no.: HEC1000AFR 1-4. Mounting plane Cutout mm (inch) Page 10...
  • Page 11: Configuration & Maintenance

    Part no.: Delta model no.: HEC1000AFR 1-5. Configuration & Maintenance Make sure the air conditioner surface sealed with mounting flange to avoid water penetrates into shelter through mounting interface. It is suggested to use gaskets sticking on the mounting flange and seal the gap between flange and cabinet with silicone gel during installation.
  • Page 12: Thermal And Airflow

    Part no.: Delta model no.: HEC1000AFR Turn off the power before maintaining. Please turn off power and remove dry contact connector while non-operating for a long time. If any abnormal acoustic noise from air conditioner happened, please turn off the product and contact with customer services.
  • Page 13: Electrical Specification

    Part no.: Delta model no.: HEC1000AFR 2. Electrical Specification  Power Supply & Alarm Connector & Indicator (1) AC Power Connect: Description Cable wire size 16 AWG 16 AWG 16 AWG (2) RS485 and J1 Connect: J1 Pin Name Description...
  • Page 14 Part no.: Delta model no.: HEC1000AFR • Normal: NC and COM dry contact output close • Alarms happening: NC and COM dry contact output open (Dry Contact will trigger when alarm happen except E2.6 and E5.1) (3) Panel operation: •...
  • Page 15 Part no.: Delta model no.: HEC1000AFR (4) Panel Operation Flowchart : ※ If no button is pressed, after 20 seconds, the panel will return to the Cabinet Temperature screen. ※ The default value of Password is 0001.  SD card & Ethernet (Optional function): The controller used communication technology to remotely control, monitor, SD card 8 GB for logging data and alarm the cooling function of the ACU.
  • Page 16: Environmental Condition

    Part no.: Delta model no.: HEC1000AFR 3. Environmental Condition  Operating Temperature -10°C ~ +55 °C (14 °F ~ +131 °F)  Storage Temperature -40 °C ~ +70 °C (-40 °F ~ 158 °F)  Operation Humidity External air loop: 0 ~ 100 % RH Internal air loop: 0 ~ 80 % RH, non-condensing ...
  • Page 17: Parameters

    Part no.: Delta model no.: HEC1000AFR 7. Parameters 7-1 Parametric Setup Display Description Range d1.01 Communication Address 1~128, (Default=21) 0 : 9600 Communication speed d1.02 1 : 19200 (Baud rate) (Default=0) Compressor turn on d1.03 20~50, (Default=40) temperature setting Compressor hysteresis set d1.04...
  • Page 18: Self-Test

    Part no.: Delta model no.: HEC1000AFR d2.03 Ambient temperature Display d2.04 Internal fan speed Display d2.05 External fan speed Display d2.06 Firmware version Display ※ d1.10 and d1.11 are option functions. Default is closed. ※ d2 layer is for system status information read only.
  • Page 19 Part no.: Delta model no.: HEC1000AFR Evaporator temperature sensor fault alarm E 3.2 Condenser temperature sensor fault alarm E 3.3 Ambient temperature sensor fault alarm E 3.4 Internal fan exception alarm(Only For DC Fan Project) Fan exception External fan exception alarm(Only For DC Fan Project)
  • Page 20 Part no.: Delta model no.: HEC1000AFR Fault Analysis and Processing Fault State Analysis of the Reasons Solutions 1. Check the power supply and Power on, and the 1. Power failure or no power. the electric circuit. cabinet temperature is 2. The target temperature is 2.
  • Page 21: Installation Notice

    Thermal Solutions product family and manufactured by Delta Electronics, Inc., herein referred to as (“products”), will be free from defects in material and workmanship for a period of one (1) year from the date of shipment by Delta Electronics, Inc. This warranty covers repair or replacement of product at the sole discretion of Delta Electronics, Inc.
  • Page 22 All returns require a Return Material Authorization number (RMA #), regardless of reason for return, whether it be for warranty or out of warranty repair. Returns without an RMA # will be refused by Delta Electronics, Inc. Approval for return requests are at the sole discretion of Delta Electronics, Inc.
  • Page 23: Reclaim

    3. Quantity to be returned and a brief description of failure for each unit, if different. All returns to Delta Electronics, Inc must be securely packed, using original cartons if possible. All returns must have the RMA number visible on the outside of the carton.
  • Page 24: Versions

    Part no.: Delta model no.: HEC1000AFR 11. Versions CHECKED ISSUE REV. DESCRIPTION DRAWN APPROVED DATE TEDTU / Rex Lyu Allen.Huang ISSUE SPEC Rex Lyu 01/30'20 ------ CW.CHEN 01/30'20 01/30'20 01/30'20 01/30'20 Page 24...