Ii.12.E) Gsm Module - TECH ST-707 User Manual

Table of Contents

Advertisement

NOTE: If the installation includes a TECH room thermostat with RS
communication (four-wire cable), you may choose an option providing dynamic
control for the mixing valve
13. Factory settings
This parameter allows you to restore the mixing valve settings saved by the
manufacturer. By restoring the factory settings you will not change the valve
type setting (central heating or floor type).
14. Valve removal
This function is used for a complete removal of the valve from the
controller memory. Valve removal is used e.g. at disassembling the valve
or module replacement (re-registration of a new module is necessary).
GSM module
II.12.e)
NOTE
Controlling of this type is possible after purchasing and connecting,
to the controller, the additional control module ST-65 which is not attached to
the regulator as a standard feature.
The GSM module is an optional device cooperating with the boiler
controller, enabling remote control of the boiler operation with the use of a
mobile phone. The User is notified with a text message on each alert of the
boiler controller, and by sending an appropriate text message at any time, he
or she receives a return message with the information on the current
temperature of all sensors. After entering an authentication code it is also
possible to remotely change the set temperatures.
The GSM module can also operate independently from the boiler
controller. It has two inputs with temperature sensors, single contact input for
use in any configuration (detecting short circuit/opening of contacts) and one
controlled output (e.g. possibility to connect additional contactor to control any
electrical circuit).
When
any
temperature, maximum or minimum, the module will automatically send a text
message with such information. It is similar in the case of a short-circuit or
temperature
sensor
reaches
- 19 -
the
preset
deactivation

Advertisement